![Bosch MIC Series 550 User Manual Download Page 33](http://html.mh-extra.com/html/bosch/mic-series-550/mic-series-550_user-manual_40696033.webp)
Keyboard Command User Action
Description
2 – Aux On / Aux
Off
Press
Activates / deactivates alarm output 2.
This command is supported with Non-IR models
only if an optional 8-input alarm card is installed in
the PSU powering the camera.
91 – Aux On
Press
Activate Zone Scan (display zone titles).
92 – Aux On
Press
Deactivate Zone Scan (re-move zone titles)
Special Preset Commands, Pelco Protocol
Some Pelco mode preset commands have a special meaning and override the normal Pelco
preset function as follows:
Preset Command Description
33-PRESET
Pans the camera 180° (Flip).
34-PRESET
Goes to Zero Pan (original home position).
80-PRESET
Toggles the Synchronization Mode between Line Lock and Internal
(Pelco Frame Scan). This command is available if commands are
unlocked using the Main menu.
81-PRESET
Initiates Preset Tour 1.
82-PRESET
Initiates Preset Tour 2.
92-PRESET
Sets the Left pan limit for an AutoScan with Limit Stops enabled.
93-PRESET
Sets the Right pan limit for an AutoScan with Limit Stops enabled.
94-PRESET
Initiates a Preset Tour.
95-PRESET
Enables or disables Limit Stops in the Setup Menu for AutoScan.
Invokes the Pelco main Setup Menu when pressed for 2 seconds.
96-PRESET
Stops a scan.
97-PRESET
Initiates FastAddress (Pelco Random Scan).
98-PRESET
Toggles the Synch. Mode between Line Lock and Internal (Pelco
Frame Scan). This command is available only for two (2) minutes after
the power is applied and then reverts to normal preset functionality.
99-PRESET
Starts an AutoScan.
Notice!
Some Pelco controllers do not support all of the preset command numbers. Refer to the
documentation of the specific Pelco controller for supported preset commands.
12.3.5
MIC Series 550
Getting Started | en
33
Bosch Security Systems, Inc.
Operation Manual
November 2011 | | F.01U.239.454