One (1) 1/2 in. NPT and one (1) M12 blanking plug
Alarm Inputs
The table below identifies the number of alarm inputs and outputs available in MIC power
supply units, depending on whether or not an 8-input alarm card is installed.
MIC PSU
8-input Alarm Card
(MIC-ALM)?
Number of
Alarm Inputs
Number of
Alarm Outputs
MIC-24PSU-2,
MIC-115PSU-2,
MIC-240PSU-2
No
1
0
Yes
8
2
Table 11.3: Number of alarm inputs and outputs in MIC PSUs
The table below identifies the number of alarm inputs and outputs available in MIC IR power
supply units. MIC IR PSUs do not have the option of a separate card for additional alarm
inputs or outputs.
MIC PSU
Number of
Alarm Inputs
Number of
Alarm Outputs
MIC-IR-24PSU-UL,
MIC-IR-115PSU-UL,
MIC-IR-240PSU-UL
4
0
Table 11.4: Number of alarm inputs and outputs in MIC IR PSUs
Simultaneous IP and Analog Video/Control ("Hybrid"
Operation)
The figure below illustrates how to configure your system to achieve simultaneous video and
control over both IP and analog connections.
11.2
11.3
MIC Series 550
Install the MIC Power Supply Unit (PSU) | en
27
Bosch Security Systems, Inc.
Operation Manual