MIC Series 500 Camera
| en
51
Bosch Security Systems, Inc.
User’s Manual
F.01U.173.601 | 2.0 | 2010.11
A
Appendices
A.1
MIC 500 Series Aux Controls
The following table identifies the Auxiliary (Aux) codes of a MIC running Bosch protocol.
Table 1.1
Au
x
Setting
Values Available
2
Auto Pan
On: Starts Auto Pan between Scan Limits.
Tilt can be adjusted.
Off: Stops Auto Pan.
3
Iris Control
On: Iris Auto
Off: Iris Manual
4
Focus Control
On: Focus Auto
Off: Focus Manual
7
Plays Pre-position Tour 2 On: Starts Tour 2
Off: Stops Tour 2
8
Plays Pre-position Tour 1 On: Starts Tour 1
Off: Stops Tour 1
9
Inactive Home Return
On: Toggles between Return Home (Preset 99) or
Return Pre-position Tour (Inactivity after 300 seconds.)
Off: Inactive Home Return OFF
50
Play Pattern Tour 1
On: Plays Pattern 1
Off: Stops playing Pattern 1
52
Play Pattern Tour 2
On: Plays Pattern 2
Off: Stops playing Pattern 2
100 Record Pattern Tour 1
On: Records Pattern 1
Off: Stops recording Pattern 1
101 Record Pattern Tour 2
On: Records Pattern 2
Off: Stops recording Pattern 2
246 Fast Address Stage 1
On: Continues to Stage 2 in Fast address reprogram
Off: Cancels fast address reprogram
292 Fast Address Stage 2
On: Continues to Stage 3, which requires controller to move
to new address and “PRESS ON 1 ENTER”
Off: Cancels fast address reprogram
401 Wiper
On: Closes Wiper Relay
Off: Opens Wipe Relay
402 Washer
On: Closes Washer Relay (Wipes if washwipe is enabled)
Off: Opens Washer Relay
417 Protocol Change Stage 1 Continues to Stage 2
418 Protocol Change Stage 2 Takes next Aux as Protocol and Address Byte
420 On Screen menu
Displays On Screen Menu