If using a High PoE
midspan
power source:
a. Connect one end of a Cat5e/Cat6 Shielded Twisted Pair (STP) Ethernet cable to the
RJ45 connector of the camera.
b. Connect the other end of the cable to the DATA + POWER OUT port on the midspan.
Note
: You must ground cable at both ends!
c. Connect a Cat5e/Cat6 Shielded Twisted Pair (STP) Ethernet cable from the DATA port
of the midspan device to the Local Area Network (LAN).
–
If
not using
High PoE: Connect a Cat5e/Cat6 Shielded Twisted Pair (STP) Ethernet cable
from the RJ45 connector of the camera to the Local Area Network (LAN).
–
If
not using PoE and if connecting directly
to a computer, DVR/NVR, or other related
network device: Connect either a Cat5e/Cat6 Shielded Twisted Pair (STP) Ethernet cable
or a
crossover
Ethernet cable between the RJ45 connector of the camera and the
network device.
Note
: You must ground cable at both ends!
2. If applicable, connect the 24 VAC wires to the power source.
3. If applicable, connect the RS-485 wires to the MIC-ALM-WAS-24 (optional).
4. Attach the ground wire from the camera to an earth-ground connection on the mounting
surface using the supplied screw or a suitable user-supplied fastener.
5. If applicable, connect the AUDIO IN and AUDIO OUT wires to the appropriate line level
audio device.