46
en | Operation
LE10 Radio Receiver
F.01U.139.675 | V1.3 | 2013.05
User Manual
Bosch Security Systems
–
Relay 2 switches on for 2 seconds.
Activation of any transmitter during these 10 seconds will
retrigger the procedure.
6.7
Daily messages in modes 1, 2 or 5
6.7.1
Daily message with battery-low signal
Device behavior
–
LED 1 stays permanently green.
Upon receiving a daily message with battery-low signal:
–
LED 2 blinks red every 10 seconds.
–
Relay 1 stays off.
–
Relay 2 switches on, until the battery is changed.
When the battery is changed, LED 2 and Relay 2 switch off if a
daily message or a transmitter activation is detected.
6.7.2
Reset of a battery-low indication with button T1
Device behavior
–
LED 1 stays permanently green.
–
LED 2 is already blinking red every 10 seconds.
Upon pressing button T1 min. 1 second, there is a reset of the
battery-low indication:
–
LED 2 turns off.
–
Relay 2 switches off.
NOTICE!
In these two modes, there is no battery-low indication.
NOTICE!
In Normal mode 2, LED 2 is deactivated regarding battery-low
indication and will not show any indication.
NOTICE!
If you disconnect and reconnect the power supply, the battery-
low indication will be reset as well.