- Read of voltage (43), rotational speed (44) and current (45).
- After test actuate the key
AKKU MINUS
(29).
LED off!
Indicator lamp (28) off.
!
Otherwise battery may discharge!
i
It is not possible to provide test values and test instructions
due to the broad range of manufacturers, types and
performance ratings available on the market.
Request the appropriate test instructions from the respective
vehicle or assembly manufacturer.
7.4.2
No-load test
This is usually done without meshing the pinion. Since, however,
the frictional resistance of the unbraked ring gear (under no load)
on the test bench is very low, the no-load values can also be
measured when the ring gear is being driven.
- Method as for load test (see chapter 7.4.1), but without
actuating the brake pedal.
7.4.3
Short-circuit test
Short-circuit testing is effected by braking the starting motor to a
standstill within 1-2 seconds using the brake pedal and at the
same time reading off the current and voltage. Blocking is to be
carried out only for a short time, maximum 2 seconds.
The test specifications given in the test-specification sheets apply
when using 143 Ah batteries, three-quarter charged. Deviations
between the test specifications and the measured values may
possibly be due to different battery sizes or state of charge.
- Method as for load test (see chapter 7.4.1), but the starting
motor is braked by actuating the brake pedal within 1-2 seconds
until it comes to a standstill.
8. Technical Specifications
Mains connection:
400 V, 50 Hz, 7,5 kW
Battery connection:
6V, 12 V, 24 V, 143 Ah or 150 Ah
Ammeter:
10-0-60 A, switchable to 20-0-120 A
Ammeter:
0-300 A, switchable to 0-1800 A
Ammeter:
0-10 A
Voltmeter:
0-10 V, 0-20 V, 0-40 V
Tachometer:
0-6000 rpm
Tachometer:
6000/12000 rpm
Brake unit for starting motor:
Hydr. drum brake
Generator drive:
electronicallly controlled drive
Dimensions:
H 1680 x W1610 x D890 mm
Use:
In an enclose, dry workshop room
Testing possibilities
Starting motors:
Securing:
Cradle- or flange-mounting
Voltage:
6/12/24 V
Current:
0-1800 A
Output:
0-6 kW (using special accessories up to
10 kW)
Modules:
m 2,5; 3; 2,116/1,814 (ring gears for other
modules available as special accessories)
Rotational speed:
0-12000 rpm
Generator:
Securing:
Cradle- or swivel-arm mounting
Voltage:
7/14/28 V extended operation
Current:
0- 65 A / 28 V extended operation
0-120 A / 28 V briefly (5% duty cycle)
Rotational speed:
0- 6000 rpm direct drive
0-12000 rpm belt drive
1500 rpm / 3000 rpm (rotational speed drive)
Space required:
2,5 m x 1,9 m
Weight:
Approx. 500 kg
8.1 Noise level according to DIN 45 635
8.1.1
Generator
Cycle:
2 min
1500 rpm / 30 A
10 min
2200 rpm / 60 A
1 min
5500 rpm / 90 A
Noise level L
WA
91,8+3 dB(A)
Workplace-related emission level L
PA
83,2 dB(A)
8.1.2
Starting motors
Cycle:
Meshing, then approx. 1 second no-load operation,
then load up to 700 A.
Noise level L
WA
96,8+3 dB(A)
Workplace-related emission level L
PA
83,2 dB(A)
The noise-emission levels are determined primarily by the
respective test piece.