![Bosch K2200 Series User Manual Download Page 13](http://html.mh-extra.com/html/bosch/k2200-series/k2200-series_user-manual_39361013.webp)
K2200 Series |
User Guide | 3.0
Administering the System
EN
| 13
Bosch Security Systems | 7/03 | 17376 v1.1 / 47491C
Figure 4:
K2200 Faceplate
1
2
3
1 -
Reader
2 -
16 Character Display
3 -
48 Key Keypad
3.1.4
Entering Editor Mode
Present the editor key to the faceplate reader. If the
key is a valid editor key or the master key:
•
You may be prompted to enter a password,
PASSWD _
In which case, use the keypad to enter the
password (maximum 8 characters) and press
[
ENT]
. If the password is valid, you will see the
CMD
prompt - see
Section 3.1.5
Command Prompt -
CMD
.
If the password you enter is not valid, you will
get:
INVALID PASSWORD
and be returned to a blank screen. Present the
key and try again. If it still does not work, ask the
person responsible for the system to check your
password.
•
If no password has been assigned to the key, you
will immediately have the CMD prompt - see
Section 3.1.5
Command Prompt - CMD
.
Note:
If the key you present is not an editor key, you will see
T
This indicates that a key has been presented, but is not
recognized as an editor key.
Note:
No alarm conditions will be reported while you are in
Editor mode, nor will any transactions be printed.
When you leave Editor mode, any alarms that occurred
will be reported and all the transactions will be
printed. Door controller or alarm module relays will
operate during Editor mode.
3.1.5
Command Prompt - CMD
The starting point for any operation within the
Editor
mode
is the
CMD
prompt:
CMD _
Here you are being prompted to enter one of the
commands that either alters the information stored in
the door controller, such as adding or deleting
personnel, or initiates an action, such as a manual
unlock.
Editor Levels
The commands you can perform are determined by
your editor level. This is set by the person
responsible for issuing editor keys. If you try to enter
a command that is not available to you, you will see:
INVALID ID LEVEL
and be returned to the CMD prompt.
Editor Time Out
Once in
Editor
mode, if you do not press any keys
for more than 3 minutes, the mode will time-out. You
will then have to present your editor key again to
return to the
Editor
mode. This means you cannot
inadvertently walk away from the system leaving it in
the
Editor
mode.
3.1.6
Leaving Editor Mode
Once you are in the
Editor
mode,
you can press the
[ESC] key at the
CMD
prompt to leave and return the
door controller to its normal operation. Any alarm
conditions that occurred while you were in the
Editor
mode
will now be reported. Also, if you have
a printer connected, any transactions that have
occurred while the
Editor
mode
was being used will
now be printed.
3.1.7
Panel Keyboard
In the
Editor
mode
the
?
key provides extra help.
For instance, at the
CMD
prompt, if you press
?
you
will see:
ENTER COMMAND
This display lasts about 3 seconds before returning to
the CMD prompt or the prompt at which you
pressed the key. You should press [?] at any time if
you are not sure what is required.