Transmitter rear view
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
0
2
4
4
5
6
2
3
1
8
10
12
14
16
18
20
22
24
26
28
30
Network
1
2
1
2
6
9
7
5
3
8
4
Figure 3.3: Transmitter, rear view
1
MIodule slot - An optional audio interface module can be mounted in the transmitter
housing. Its connectors are accessible via an opening at the back of the transmitter.
2
Emergency switch connector - A terminal block socket for a single, 'normally open'
switch. When the switch is closed, the audio signal on the Aux-right input is distributed
on all output channels, overriding all other audio inputs. A matching cable connector is
provided.
3
Auxiliary audio inputs - Two female XLR connectors for extra audio inputs. They can be
used to connect auxiliary symmetrical audio signals such as a music installation, the
original floor language or emergency messages.
4
Audio signal inputs - 4, 8, 16 or 32 cinch plugs to connect external asymmetrical audio
input signals. The number of connectors depends on the transmitter type.
5
Earth connection point - Only used for factory testing purposes.
6
Radiator signal loop-through input - A HF BNC connector to loop-through the radiator
output of another transmitter.
7
Radiator signal outputs - Six HF BNC connectors, used to connect the radiators. Up to
30 radiators can be loop-through connected to each output.
8
Optical network connections - Two connections used to connect directly to the DCN
Next Generation conference system with an optical network cable.
9
Mains input - Euro mains socket. The transmitter has automatic mains voltage selection.
A mains cable is provided
The following sections give more information about the mentioned subject:
–
Installation: Integrus Transmitters, page 33
–
Connection: Connection, page 42
–
Configuration: Integrus transmitter, page 48 and Setup the transmitter, page 51
–
Operation: Integrus transmitter, page 69
12
en | System Overview
Language Distribution System
2013.11 | V1.4 |
Operation manual
Bosch Security Systems B.V.
Summary of Contents for INT-TX04
Page 1: ...Language Distribution System Integrus en Operation manual ...
Page 2: ......
Page 93: ......