68 | HTD 6xx / HTD 8xx | Checking / calibration
en
4.
Select "MEASURING INSTRUMENT".
5.
Select "SENSOR".
T
he values displayed now are not correct, they indi-
cate merely that the height sensor was detected.
6.
Click on the button "ON" to start the calibration.
7.
Follow the instructions on the screen and position
the light box at the indicated heights. Then press the
button "ON again" .
8.
Click on the button
to return to the "SERVICE"
screen.
4.7
Measuring instrument (height sen-
sor)
1.
Click on "OPTIONS" in the main menu.
2.
Click on "SERVICE" in the "OPTIONS" screen.
3.
Enter PIN: 835231.