1 692 106 011
2019-03-26
|
Robert Bosch GmbH
Checking / calibration | HTD 6xx / HTD 8xx | 63
en
1
Fig. 10:
Laser line through opening of vertical laser
1 Opening of vertical laser
4.
Turn on vertical laser and check if the green vertical
laser line is congruent with the cross lasers' red line.
Fig. 11:
Checking the congruence of vertical laser
Fig. 12:
Parallelism laser lines
5.
If necessary, set laser line of vertical laser parallel to
the vertical laser line of the cross laser by using the
adjusting screws.
1
1
1
Fig. 13:
Parallel adjustment
1 Adjusting
screws