1 692 106 011
2019-03-26
|
Robert Bosch GmbH
Checking / calibration | HTD 6xx / HTD 8xx | 67
en
10.
Also perform the high beam test.
11.
Compare the two intensity values with the speci-
fied intensity value for the calibration unit.
In the event of deviations, proceed at item 12.
12.
Click on "OPTIONS" in the main menu.
13.
Click on "SERVICE" in the "OPTIONS" screen.
14.
Enter PIN: 835231
15.
Click on "CALIBRATION" in the "SERVICE" screen.
16.
Calculate the correction factor ("D") for the low
beam as follows:
i
D = Correction factor
Ikal = Set intensity value of calibration device (de-
vice label)
Iseg = Measured intensity value of headlamp beam
setter
D.Alo = Current correction factor
D = (Ikal/Iseg) × D.Alo
17.
Alter the low beam value "D" by way of the + or -
buttons on the right and save the value.
18.
Press the headlamp symbol to switch to high beam.
19.
Repeat items 16 and 17 for the high beam.