Gas cooktops only:
Install gas cooktop seal kit
(purchase separately)
Available for application with gas cooktops - where proper
sealing is required and holes are required in cabinet base.
Kit includes trim seal, toe-kick cover plate, and cabinet hole
cover plate.
Installation instructions are included with the gas cooktop
seal kit.
Install roof cap, wall cap, inline or
remote blower
1. Follow instructions included with caps, inline and remote
blower.
Connect ductwork
1. From roof cap, wall cap, or remote blower - work back
towards the cabinet, attaching all ductwork, elbows and
transitions as previously planned.
2. Connect ductwork (and transition, if required) to lex blower
or downdraft. If necessary, use (2) #8-18 x .375 (9.5mm)
Phillips screws for transition.
Note: Regardless of blower placement/exhaust, ensure
that all seams are properly taped - to make them secure
and air-tight. This includes seams/gaps between panels
and/or on the blower.
Install the electrical panel
(if previously removed from downdraft housing)
1. If electrical panel was removed from the downdraft housing
in order to mount it in a remote location: Mount electrical
panel in chosen location.
Note: Do not mount electrical panel with slots in cover
facing downward.
Plan house wiring
WARNING
RISK OF ELECTRIC SHOCK
Parts inside the appliance can have sharp edges. The
connection cable can be damaged. Do not bend or
pinch connection cables during installation.
Before connecting the appliance, check the house wiring
to make sure it has suficient circuit protection. The voltage
and frequency of the appliance must match the electrical
installation (see rating plate).
Only a qualiied electrician following all appropriate
regulations may lay or replace the connecting cable.
Follow all regulations, codes, and laws.
Ensure that the electrical connection meets the
requirements of the latest version of all regulations,
codes, and laws in the appropriate country, especially the
following standards:
National Electrical Code, ANSI/ NFPA 70*, or CSA
Standards C22.1-94, Canadian Electrical Code, Part 1
and C22.2 No.0-M91**, UL 507.
Have a qualiied electrical technician check the grounding
of the appliance.
Do not ground to a gas line.
Keep these installation instructions for future reference.
Ensure that the wire diameter meets the requirements of
the latest version of all applicable regulations, codes, and
laws in the appropriate country, especially the following
standards:
National Electrical Code, ANSI/NFPA 70*, or CSA
Standards C22.1-94, Canadian Electrical Code, Part 1
and C22.2 No.0-M91**.
The downdraft with the Flex Blower (purchase separately)
draws 3.0 Amps and requires a 120 VAC, 60 Hz circuit.
The downdraft with Remote Blower Models DHG6015NUC
and DHG6023RUC (purchase separately) draws 5.0 Amps
(max.) and requires a 120 VAC, 60 Hz circuit.
The downdraft has a 30-in. (762mm) long power cord with
a 3-pronged plug. Plan to provide a grounded outlet in a
location which will allow the power cord to reach.