English 14
Prepare downdraft housing
1. Place the downdraft on its back on a table or lat work
surface.
2. Slide upper support brackets into slide channel at top
left and right of unit.
Attach long or short support legs (depending upon
cabinet height) to bottom sides of unit with hex screws
provided. Do not tighten hex screws completely at this
time.
UPPER
SUPPORT
BRACKET
SLIDE
CHANNEL
SUPPORT
LEGS
HEX SCREW
1/4-20 X .500 (12.7MM)
Optional: Electrical panel can be
mounted in a remote location.
Example: There is a drawer
at the bottom of the
cabinet, in front of the
downdraft. This
may require the
electrical panel
to be mounted in
an adjacent cabinet.
If blower discharge is
down, electrical panel
must be relocated.
1. Remove (2) #8-32 hex nuts and
electrical panel. Do not mount with electrical panel slots
facing downward.
2. Installation of a remotely located electrical panel may
be completed after connecting the ductwork and install
the blower. Install electrical panel according to local
codes.
INSTALLATION
#8-32 HEX
NUTS
INTERCONNECT CABLE (5-FT. (1.5 M) LONG)
Note:
Interconnect
cable may be
unplugged (as shown)
if it helps in routing
of cables for remote
installation of electrical
panel.
Installation with Gas Cooktops
Cooktop cutout width
1-7/8” (48)
BT
MIN.
1/2”
(13)
Downdraft cutout width:
30” (762) is 27-1/16” (687)
36” (914) is 33-1/16” (840)
Template
2-1/8” (54)
19-1/8” (486)
22-5/16” (567)
24-11/16” (628)
1-1/16”
(27)
Dimension “BT” is thickness of
the backsplash that provides
1/2” (13mm) clearance
between the vent and the
backsplash. Any backsplash
with a curved radius where it
meets the counter will require
additional clearance. Thicker
backsplashes may be used
by increasing the counter and
cabinet depths.
Set the cooktop into the
coutertop opening so that
the back edge of the cooktop
overlaps the leading edge of
the downdraft.
Measurements in inches (mm).