![background image](http://html.mh-extra.com/html/bosch/hagglunds-cb/hagglunds-cb_installation-and-maintenance-manual_42986020.webp)
20/68
Transport and storage
Bosch Rexroth Mellansel AB
,
Installation and maintenance manual , Hägglunds CB, RE 15302-WA/05.2019
Fig. 11: Filling the motor with oil
6.2.2 Storing for extended periods or in uncontrolled environment
NOTICE
Insufficient cleanliness!
Risk of damage to equipment.
▶
Take extreme care to ensure that no contamination enters the motor.
If the motor is stored for more than 3 months in uncontrolled environment or more
than 12 months in controlled environment, it must be totally filled with oil according
to below:
1
Place the motor as shown in
Fig. 10
, B) Standing with shaft vertical.
2
Fill the motor full with filtered oil containing a mixture of 2% Shell VSI 8235, or
similar compatible corrosion inhibitor in the selected fluid in the following order:
D1, A1, C1.
NOTE!
See
Table 6
for oil volume.
3
Fit the plug to D1.
4
Seal connections A1 and C1 with the cover plates fitted to the connection surface
at delivery. Check that the O-rings or rubber seals are in position in the cover
plates
5
Position the motor as shown in
Fig. 10
,
A) Standing with shaft horizontal or alt.
B) Standing with shaft vertical.
6
The motor must be turned a few revolutions once a month to prevent internal
corrosion in the motor.
A1
C1
D1
DD00100068
Motor size
Motor case oil volume including channels
Litre
US gallon
CB 280
15
4.0
CB 400
21
5.5
CB 560
19
5.0
CB 800
25
6.6
CB 1120
32
8.5
Table 6: Motor case oil volume
Cover plate