66/68 Troubleshooting
Bosch Rexroth Mellansel AB
,
Installation and maintenance manual , Hägglunds CB, RE 15302-WA/05.2019
Fault
Probable cause
Action
The motor does not run.
Mechanical stop in the drive.
Check system pressure. If the pressure has
risen to the relief valve setting, remove the load
from the drive.
The motor does not deliver enough torque
because the pressure difference across the
motor is not enough for the load.
Investigate the pressure level in the system and
correct the setting of the pressure limiting valve
if necessary.
Insufficient or no oil being supplied to motor.
Check the hydraulic system. Check the external
leakage of the motor (D connection).
Motor rotates in wrong direction.
Oil supply connections to motor incorrectly
connected.
Connect the oil supply correctly.
Motor runs rough.
Pressure or flow fluctuations in the hydraulic
system.
Find the cause in the system or in the driven
unit.
Noise in the motor.
The motor is being operated with too low
charge pressure.
Adjust the charge pressure to the correct level.
See chapter Recommended charge pressure in
data sheet
RE 15302.
Internal faults in the motor.
Investigate the drain oil, if necessary. Put
a magnetic plug in the oil flow and check
the material that sticks to the magnet. Steel
particles indicate damage. Note that fine
material from the castings may be deposited
and does not mean internal damage in the
motor.
External oil leakage on the motor.
The radial lip seals or other seals is worn or
damaged.
Replace the damaged seals.
14 Troubleshooting
Please, contact your nearest Bosch Rexroth representative.
Table 20: Troubleshooting hydraulic motor