48/68 Installation
Bosch Rexroth Mellansel AB
,
Installation and maintenance manual , Hägglunds CB, RE 15302-WA/05.2019
Fig. 45: Horizontal mounting
Flushing flow inlet
Alternative flushing flow
inlet for flange mounted
motors.
DD00087718
Drain line connection
D1
D2
D3
D4
7.4.5 Draining and venting the motor
Horizontal mounting
When the motor is installed with the shaft in the horizontal plane, the highest of the
four drain outlets D1, D2, D3 or D4 must always be used see
Fig. 45
.
Drain line must be connected to the tank with a minimum of restrictions, to ensure
that the maximum case pressure is not exceeded.