Page 12 from 76 6 720 814 719
SM FP_Australia 2017/04 EN
WRAF0106
Pict 13 – Remote control view and software version sticker location
4.2
Heat cell with burner pipes
The heat cell includes the flame visualization window, ignition electrode, ionization electrode and the burner
pipes.
Inlet: Primary air from the fan and gas from the gas manifold.
Outlet: Hot combustion gases to the heat exchanger
Pict.14 – Heat cell detail with ignition / ionization electrodes and burner blade detail
Primary air plate
The primary air plate is assembled between the heat cell and the gas manifold in order to ensure the correct
mixture of air and gas according to the specific appliance model.
Platform
Appliance
Stamp
Low output (ind
/ out)
12l/min
12 L
16l/min
18 L
20l/min
20 L
High output
(out)
16l/min
code
20l/min
code
26 l/min
code
Table 10 – Identification of primary air plates
The plate has indexation pins that ensure the correct assembly on the heat cell and the type gas mark