Page 75 from 76 6 720 814 719
SM FP_Australia 2017/04 EN
F7
Ionization detected with appliance in standby
Characteristic: Ionization system
Lock Out Error
Burner shutdown
F9
Safety solenoid valve disconnected
Characteristic: electro valve
Lock Out Error
Burner shutdown
FA
Gas leakage error due to failure in gas valve that is not closing properly
Characteristic: Gas Valve + Ionization system
Loose or bad connection
between cable and
electrode
Assure black wire is
securely connected to
the set of electrode
Ionization cable
damaged / defective
isolation ?
Replace wiring and
assure connection in
electrode
Yes
No
Ionization electrode
damaged?
Replace electrode
Yes
Verify wires connection:
SV1
– blue wires
SV2
– white wires
SV3
– black wires
Measure resistance of
SV
≈ 99.7 Ω
No
Loose connection in
safety solenoid (SV1 /
SV2 / SV3)
Problem solved?
Replace gas valve
Replace control unit
No