6 720 800 817 (2012/02)
Menu settings INSTALLER SETTINGS (for contractors only)
|
43
8.1.2 INSTALLER SETTINGS: Heating parameters
8.1.3 INSTALLER SETTINGS: Solar system config
8.1.4 INSTALLER SETTINGS: Solar sys parameters
Menu structure
Heating parameters
Factory
setting
Setting range
Personal
setting
Description
from page
Calibrate room temperature
sensor
0.0 K
– 3.0 K ... 3.0 K
K
46
Adjustment factor I
40 %
0 % ... 100 %
%
Amplification factor V
80 %
40 % ... 100 %
%
Heat-up optimisation
No
No | Yes
Maximum CH flow temperature 75 °C
30 °C ... 85 °C
°C
Mixer running time
140 s
10 s ... 600 s
s
Menu structure
Solar system config
Factory
setting
Setting range
Personal
setting
Description
from page
Solar sys option E Thermal
disinfection
No
No | Yes
47
Menu structure
Solar sys parameters
Factory
setting
Setting range
Personal
setting
Description
from page
1. Standard system
–
–
–
48
SP: ON temperature
difference
8 K
3 K ... 20 K
(not lower than “SP: OFF
temperature difference” +1 K)
K
SP: OFF temperature
difference
4 K
2 K ... 19 K
(not higher than “SP: ON
temperature difference” – 1 K)
K
T2: Max. solar cylinder
temperature
60 °C
15 °C ... 90 °C
°C
Maximum collector
temperature
120 °C
100 °C ... 140 °C
°C
SP: Collector grp 1 pump
mode
Auto
Auto | Manual On | Manual Off
PE: Therm disinfect pump
mode
Auto
Auto | Manual On | Manual Off
47
Solar optimisation
49
Collector group 1 area
0.0 m
2
0.0 m
2
... 150.0 m
2
m
2
Collector group 1 type
Flat plate
collector
Flat plate collector | Vac tube
collector
Climate zone
90
0 ... 255
Optimizing influence DHW
0 K
0 K (= function off) ... 20 K
K
Run solar system
No
No | Yes
48