Analysis type
Select the required analysis algorithm. By default, only
is available – this offers a motion detector and essential recog-
nition of tampering. The current alarm status is displayed for
information purposes.
7.12.3
Motion detector
Motion detection is available for the
analysis type. For
the detector to function, the following conditions must be met:
–
Analysis must be activated.
–
At least one sensor field must be activated.
–
The individual parameters must be configured to suit the
operating environment and the desired responses.
–
The sensitivity must be set to a value greater than zero.
i
NOTICE!
On the
Livepage configuration
page, you can enable additional
information overlays for the live video image too (see “Livepage
configuration” on page 91).
i
NOTICE!
Additional analysis algorithms with comprehensive functions
such as IVMD are available from Bosch Security Systems.
i
NOTICE!
Reflections of light (off glass surfaces, etc.), switching
lights on or off or changes in the light level caused by cloud
movement on a sunny day can trigger unintended responses
from the motion detector and generate false alarms. Run a
series of tests at different times of the day and night to ensure
that the video sensor is operating as intended.
i
NOTICE!
For indoor surveillance, ensure constant lighting of the areas
during the day and at night.