en | Troubleshooting
FlexiDome
DN
IP
V 1.0 | 2006.12
Operating Instructions
Bosch Security Systems
The unit does not
report an alarm.
Alarm source is not
selected.
Select possible alarm sources on
the
Alarm sources
configuration
page.
No alarm response speci-
fied.
Specify the desired alarm
response on the
Alarm connec-
tions
configuration page, if neces-
sary change the IP address.
The unit is not opera-
tional after firmware
upload.
Power failure during pro-
gramming by the update file.
Have the unit checked by Cus-
tomer Service and replace if neces-
sary.
Incorrect update file.
Enter the IP address followed by
/
main.htm
in your web browser
and repeat the upload.
No LUNs are dis-
played after connect-
ing to the iSCSI
server.
iSCSI server configuration
has incorrect LUN mapping.
Check iSCSI server configuration
and reconnect.
LUN FAIL is dis-
played under a node
after connecting to
the iSCSI server.
The LUN list could not be
accessed because it was
assigned to the wrong net-
work interface.
Check iSCSI server configuration
and reconnect.
LUN mapping not
possible.
The iSCSI system does not
support the use of initiator
identification.
Delete the identity on the iSCSI-
parameter configuration page.
Malfunction
Possible causes
Solution