14
Fig 19
7
Installation of connection lines
7.1 Installing the dummy hose pipes
Remove the plastic protection cap from the header
pipe.
Insert the hose clamp into the hose
Insert the dummy hose with hose clip into the
header tube.
Tighten the hose clamp rigidly using screw driver.
Fig 20
7.2 Connecting the cold water hose pipe
Fig 21
Connect one end of EPDM hose to the bottom
Header pipe of the second collector.
Fix the hose pipe support bracket to the
second collector.
Connect other end of EPDM hose to the cold
water outlet pipe of the tank using hose clamp.
Route the hose pipe through support bracket.
7.3
Connecting hot water inlet pipe
Fig 22
Remove the plastic cap from the header pipe.
Insert one end of the EPDM hose into the
collector header and clamp is rigidly with hose
clamp.
Connect the other end of the hose pipe to hot
water inlet pipe of the tank.