P102 = Alarm and Relay
PIN 1
Alarm_IN1 (Alarm Input 1)
PIN 2
Alarm_IN2 (Alarm Input 2)
PIN 3
Alarm_IN3 (Alarm Input 3)
PIN 4
Alarm_OUT1 (Alarm Output 1)
PIN 5
Alarm_OUT2 (Alarm Output2)
PIN 6
Alarm_GND (Alarm Ground)
PIN 7
Relay_NO (Relay Normally Open)
PIN 8
Relay_COM (Relay Common)
PIN 9
Relay_NC (Relay Normally Closed)
P101 = Audio
PIN 1
Audio IN+
PIN 2
Audio IN-
PIN 3
Audio OUT+
PIN 4
Audio OUT-
PIN 5
Future use
PIN 6
Future use
PIN 7
Future use
5. Feed the Ethernet cable with an RJ45 connector through one of the four 3/4-in. conduit
entries. Connect the RJ45 connector of the Ethernet cable to the RJ45 terminal inside the unit
(item 1 in the following figure).
Figure 6.4: RJ45 connector
6. If desired, install the OFC Kit. Follow the installation instructions provided in the kit.
If the optional OFC kit has been installed, connect a terminated fiber optic cable to the female
ST connector.
7
. Clean and grease the O-ring and threads before replacing the front end cap. Refer to
Installation Overview, page 17.
8
. Replace the front end cap.
9
. Tighten the front end cap using the multi-use tool. Ensure that the O-ring is properly
seated. After tightening, ensure that there is no gap between the cap and the body of the
housing.
1
0
. Tighten the set screws on the front end cap using the supplied hex key.
EXTEGRA IP 9000 FX
Connections | en
25
Bosch Security Systems
Installation Manual / Guide d'installation
2016.02 | 1.2 | F.01U.319.357