P102
P101
1
9
1
7
AudioIN-
A
AudioOUT
-
(Future
use)
Alarm_IN1
Alarm_IN2
Alarm_IN3
Alarm_OUT1
Alarm_OUT2
Alarm_GND
Relay_NO
Relay_COM
Relay_NC
S100
P103
1
2
LINE
NEUTRAL
(Future
use)
(Future
use)
Figure 6.2: User Connections on User Interface Board for 24 VAC (P103), Alarm and Relay (P102), and Audio (P101)
To make connections, follow these steps.
1. Loosen the set screws on the rear end cap using the supplied hex key. Loosen the rear end
cap using the multi-use tool. To prevent damage to the o-ring, for every half turn
counterclockwise turn back one quarter-turn clockwise.
Note: To prevent damage to the cap threads, take care not to drop the end caps.
Figure 6.3: Removal of end cap with multi-use tool
2. Unscrew the rear end cap by hand. Set the cap aside.
3. Feed the 24 VAC cable through one of the four 3/4-in. conduit entries. Feed the following
cables as necessary through any one of the four 3/4-in. conduit entries: the fiber optic cable,
the alarm and relay cables, and the audio cable.
4. Make the connections to the terminal connectors.
–
Remove the terminal connectors from the User Interface Board (if necessary).
–
Make the connections, using the following three tables of pin outs as reference.
–
Insert the terminal connectors on the User Interface Board.
P103 = 24VAC IN
PIN 1
LINE24V
PIN 2
NEUTRAL24
24
en | Connections
EXTEGRA IP 9000 FX
2016.02 | 1.2 | F.01U.319.357
Installation Manual / Guide d'installation
Bosch Security Systems