70
en | Turning on the power and checking for problems in an E2700 controller-drive tray configuration
DSA E-Series (E2700)
2015.10 | V2 | DOC
Installation manual
Bosch Sicherheitssysteme GmbH
E2700 controller-drive tray failure identifications
Component
Seven-segment display used in this controller
state
Code (see
1
)
Power-on
diagnostics
Suspended
Operational
Processor DIMM (dx +) (see
2
)
yes
yes
no
Cache DIMM (CX +)
yes
yes
no
Host card (HX +)
yes
yes
yes
Flash drive (FX +)
no
no
yes
Category delimiter (--)
After (--), a “CF” (for component failure) is
displayed, followed by one of the codes
specified above.
The separator between
category- detail code pairs
is used when more than
one category detail code
pair exists in the sequence.
End-of-sequence delimiter
Appears as a blank space.(see
3
)
The end-of- sequence
delimiter is automatically
inserted by the hardware at
the end of a code
sequence.
1
A two-digit code that starts a dynamic display sequence.
2
The plus (+) sign indicates that a two-digit code appears with the Diagnostic LED on.
3
No codes display, and the Diagnostic LED is off.
12.11
Things to Know – Lock-Down Codes for the Controller-Drive
Tray
Use the following table to determine the diagnostic lock-down code definitions on the seven-
segment display in the controller canister. In general, these diagnostics display only when the
controller is in a non-operational state. The controller can be in a non-operation state as a
result of a configuration problem (such as mismatched controller types) or as a result of a
hardware fault. If the amber controller service action required LED is on, the non-operational
state is the result of a hardware fault.
Supported diagnostic lock-down codes on the seven-segment display
Diagnostic Code
Description
– –
The firmware is booting.
L0
The controller types are mismatched, which result in a suspended
controller state.
L2
A persistent memory error has occurred, which results in a
suspended controller state.
L3
A persistent hardware error has occurred, which results in a
suspended controller state.
L4
A persistent data protection error has occurred, which results in a
suspended controller state.
Summary of Contents for DSA E-Series (E2700)
Page 1: ...DSA E Series E2700 DSA N2E7Xx xxAT DSX N1D6Xx 12AT DSX N6D6Xx 60AT en Installation manual ...
Page 2: ......
Page 78: ......