64
en | Turning on the power and checking for problems in an E2700 controller-drive tray configuration
DSA E-Series (E2700)
2015.10 | V2 | DOC
Installation manual
Bosch Sicherheitssysteme GmbH
LEDs on the ESM canister
90001-01
11
12
1
2
3
4
5
9
10
6
8
7
Location
LED
Color
On
Off
1
Host link 1 fault
Amber
At least one PHY of the four
connectors is working, but
another PHY cannot establish
the same link to the device
connected to the Host IN
port connector.
No link error has occurred.
2
Host link 1 active
Green
At least one of the four PHYs
in the In port is working, and
a link exists to the device
connected to the Host In
connector.
A link error has occurred.
3
Host link 2 fault
Amber
At least one PHY of the four
connections is working, but
another PHY cannot establish
the same link to the device
connected to the Host In
port connector.
No link error has occurred.
4
Host link 2 active
Green
At least one of the four PHYs
in the IN port is working, and
a link exists to the device
connected to the Host In
connector.
A link error has occurred.
5
Ethernet link active
Green
The link is up. (The LED
blinks when there is activity.)
The link is not active.
6
Ethernet link rate
Green
There is a 100BASE-T rate.
There is a 10BASE-T rate.
7
ESM expansion link
fault
Amber
At least one of the four PHYs
in the Out port is working,
but another PHY cannot
establish the same link to the
Expansion Out connector.
Normal status.
8
ESM expansion link
active
Green
At least one of the four PHYs
in the Out port is working,
and a link exists to the
device connected to the
Expansion Out connector.
A link error has occurred.