en | Turning on the power and checking for problems in an E2700 controller-drive tray configuration
DSA E-Series (E2700)
2015.10 | V2 | DOC
Installation manual
Bosch Sicherheitssysteme GmbH
S2
The SBB Signature/Revision is invalid, which results in a
suspended controller state.
S3
An unsupported enclosure is detected in the storage array, which
results in a suspended controller state.
S4
The power supply is incapable of powering the controller, which
results in a suspended controller state.
S5
The SBB pairing fails, which results in a suspended controller
state.
12.12
Things to know – seven-segment display use cases
The following table shows both startup errors and operation errors that can be used to point
to a component failure.
Seven-segment display uses cases with repeating sequences
Use cases
Repeating sequence
Use case
: Controller power-on
–
Normal power-on controller insertion
–
Controller inserted while held in reset
SE+ 88+ blank-
Use cases
Repeating sequence
Use case
: Operational states
–
Normal operation
xy- (static controller tray ID)
–
Start-of-day (SOD) processing
OS+ Sd+ blank-
–
The controller is placed in reset while showing the
tray ID.
OS+ OL+ blank-
–
The controller is operating on batteries (cache
backup).
OS+ bb+ blank-
–
The CPU temperature has exceeded the warning
level.
OS+ OH+ blank-
Use cases
Repeating sequence
Use case
: Component failure when the controller is
operational.
–
Failed host interface card
OS+ CF+ HX+ blank-
–
Failed flash drive
OS+ CF+ Fx+ blank-
Use cases
Repeating sequence
Use case
: Power-on diagnostic failure