DINION capture 5000 IP
Advanced Mode | en
103
Bosch Security Systems, Inc.
Installation Manual
| 1.0 | 2012.01
8.7
Interfaces
8.7.1
Alarm input
Configure the alarm triggers for the camera.
Select
N.C.
(Normally Closed) if the alarm is to be triggered by
closing the contact.
Select
N.O.
(Normally Open) if the alarm is to be triggered by
opening the contact.
Select
None
to disable the input.
Note
: Input 1 is reserved for Automatic Mode Switching.
Name
Enter a name for the alarm input. This name can be displayed
below the icon for the alarm input on the
LIVEPAGE
. (Do not
use any special characters, for example &.)
Action
Select the camera mode to switch to when alarm input 1 is
triggered.
Note:
See
Section 8.6.8 Alarm Task Editor, page 102
, for information
on alarm actions based on alarm inputs.
8.7.2
Relay
Configure the switching behavior of the relay output.
Select different events that automatically activate an output.
For example, turn on a floodlight by triggering a motion alarm
and then turn the light off again when the alarm has stopped.
Idle state
Select
Open
for the relay to operate as an N.O. contact, or
select
Closed
if the relay is to operate as an N.C. contact.
Select
Select
External device
or
/IVA
to trigger the relay.
Relay name
The relay can be assigned a name here. The name is shown on
the button next to
Trigger relay
. The
LIVEPAGE
can also be
Summary of Contents for DINION 5000 IP