88
en | Advanced Mode
DINION capture 5000 IP
| 1.0 | 2012.01
Installation Manual
Bosch Security Systems, Inc.
signal. The connected monitor only displays images when an
alarm is triggered. If a particular video output is selected and a
split image is set for this output on the receiver, select the
decoder from
Decoder
in the receiver that is to be used to
display the alarm image. Refer to the destination device
documentation concerning image display options and available
video outputs.
Decoder
Select a decoder of the receiver to display the alarm image. The
decoder selected has an impact on the position of the image in
a split screen.
SSL encryption
SSL encryption protects data used for establishing a
connection, such as the password. By selecting
On
, only
encrypted ports are available for the
Remote port
parameter.
SSL encryption must be activated and configured on both sides
of a connection. The appropriate certificates must also have
been uploaded. Configure and activate encryption for media
data (video, metadata) on the
Encryption
page.
Auto-connect
Select
On
to automatically re-established a connection to one
of the previously specified IP addresses after each reboot,
connection breakdown, or network failure.
Audio
Select
On
to transmit the audio stream with an alarm
connection.