D8125 Operation and Installation Guide
D8125
Page 30
© 2004 Bosch Security Systems, Inc.
74-04247-000-N
Installation
In the
vertical
mode with
one
POPEX Module:
• Only four zones of the D8112G1/G2 can be used in the ZONEX system.
• Zones must be used in groups (Zones 1 through 4, or Zones 5 through 8).
• Up to 16 POPITs can be assigned to D8112G1/G2 master Zones 1-3 or 5-7.
• A maximum of 15 POPITs can be assigned to D8112G1/G2 Zones 4 and 8.
• A maximum of 63 POPITs can be installed.
In the
vertical
mode with
two
POPEX
Modules:
• Up to 16 POPITs can be assigned to D8112G1/G2 Master Zones 1-3 or 5-7.
• POPEX #1 assigns a maximum of 16 POPITs to D8112G1/G2 zones 1 through 3.
• POPEX #2 assigns a maximum of 16 POPITs to D8112G1/G2 Zones 5 through 7.
• Only 15 POPITs can be assigned to D8112G1/G2 Zones 4 and 8.
• A maximum of 126 POPITs can be installed.
Table 7 and Table 8 display all POPIT assignment switch settings for both the horizontal and vertical modes (e.g., 1 2 3 4 - -).
Numbers 1 through 6 indicate switches 1-6 on the POPIT Module. The dash (-) indicates a switch is in the OFF or open
position. These switches assign each point of protection to a master zone (refer to Section 3.2.6 POPIT Module Point
Assignments for switch settings). Table 7 and Table 8 indicate the maximum number of POPITs that can be assigned to each
D8112G1/G2 master zone, with one and two POPEX Modules.
Below the switch setting is the I.D. code (e.g., ZN 104) for each POPIT. The master zone and expansion point (point of
protection) are used to cross-reference the POPIT Module to an event displayed on the D1252A Command Center. For
example, in the I.D. code
ZN104
, “ZN1” indicates that the POPIT is assigned to master zone 100 of the D8112G1/G2 Control
Panel, and “04” indicates that the POPIT reports as expansion point #4.