background image

36

en | Specifications

2016.07 | 04 | F.01U.291.483

UL Installation Guide

Bosch Security Systens, Inc.

Compatible Accessories

1

Model

Title

UL 864

UL
985

Intrusion cUL

Intrusion

ICP-EZTS

Tamper Switch

X

X

X

ZX776Z

PIR Motion Sensor [15 m (50 ft)] with POPIT

X

ZX794Z

PIR Motion Sensor [24 m (80 ft)] with POPIT

X

ZX865

PIR/Microwave Motion Sensor with POPIT

X

ZX938Z

PIR Motion Sensor with POPIT

X

ZX970

PIR/Microwave Motion Sensor with POPIT

X

RFBT-A

3

RADION speciality

X

RFDL-11-A

3

RADION TriTech

X

RFDW-RM-A

3

RADION contact RM

X

RFDW-SM-A

3

RADION contact SM

X

RFSM-A

3

RADION smoke

X

X

RFRP-A

3

RADION repeater

X

X

RFPR-12-A

3

RADION PIR

X

RFPR-C12-A

3

RADION PIR C

X

RFUN

3

RADION universal transmitter

X

RFPB-TB-A

3

RADION panic

X

RFPB-SB-A

3

RADION panic

X

RFKF-TB-A

3

RADION keyfob

X

RFKF-FB-A

3

RADION keyfob

X

1

Where the fire alarm transmitter is sharing on-premise communications equipment, the shared equipment must

be UL Listed (ITE or fire protective signaling).

2

Version 1.04 or above.

3

Compatible with version 2.xx or higher

4

Refer to Two-Wire Smoke Detectors section in the Approved Applications chapter in the D9412GV4/D7412GV4

v2.02 Installation and System Reference Guide (P/N: F01U265457) for a listing of compatible two-wire smoke
detectors (Household Fire Alarm Applications only).

5

A B450 plug-in communicator interface module is required in order to use the B44x cellular communicator.

6

Check for availability in your region.

Table 5.5: Compatible Accessories

1

5.4

Circuit Classes

Onboard Points

Onboard points, points 1 to 8, are Class B, Style B Initiating-Device Circuits.

Zonex Bus or Buses

Zonex buses are Class B, Style 4 Signaling Line Circuits.

Summary of Contents for D7412GV4

Page 1: ...D9412GV4 D7412GV4 v2 03 en UL Installation Guide ...

Page 2: ......

Page 3: ...m 14 3 4 SDI and Zonex Devices Wiring Diagrams 15 3 4 1 D9412GV4 SDI and Zonex Devices B420 B426 B450 D1255 D1255RB D1256RB D1257RB D1265 D8125 D8128D D8129 DX4020 ITS DX4020 G D9210C D9127U T System Wiring Diagram 15 3 4 2 D7412GV4 SDI and Zonex Devices B420 B426 B450 D1255 D1255RB D1256RB D1257RB D1265 D8125 D8128D D8129 DX4020 ITS DX4020 G D9210C D9127U T System Wiring Diagram 16 3 5 D9412GV4 D...

Page 4: ...f contents 2016 07 04 F 01U 291 483 UL Installation Guide Bosch Security Systens Inc 5 Specifications 29 5 1 B520 Specifications 31 5 2 Terminal Wiring Requirements 32 5 3 Compatibilities 34 5 4 Circuit Classes 36 ...

Page 5: ...arks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly 1 2 Bosch Security Systems Inc product manufacturing dates Use the serial number located on the product label and refer to the Bosch Security Systems Inc website at http www boschsecurity com datecodes The following image shows an example of a product label and ...

Page 6: ...eference Guide P N F01U265457 D9412GV4 D7412GV4 v2 03 Owner s Manual P N F01U287176 2 2 Enclosure Options Mount the control panel assembly in any of the enclosures listed below D8103 Universal Enclosure tan D8109 Fire Enclosure red for the D9412GV4 and D7412GV4 Control Panels D8108A Attack Resistant Enclosure tan Refer to the Approved Applications chapter inside the D9412GV4 D7412GV4 v2 03 Install...

Page 7: ...k down tab 2 4 Installing the Control Panel 1 Place the control panel over the inside back of the enclosure aligning the large rectangular openings of the mounting skirt with the mounting hooks of the enclosure Slide the control panel down so that it hangs on the hooks Refer to Figure 2 1 2 Remove the tape from the 6 x 1 4 in screw in the mounting tab on the control panel The screw passes through ...

Page 8: ...und Fault Detect Enable Notice To meet UL 864 requirements enable Ground Fault Detect A ground fault is a circuit impedance to earth ground The control panel has a ground fault detection circuit that when enabled detects ground faults on Terminals 1 to 9 and 11 to 36 The control panel also detects and annunciates ground faults on any device connected to it If a ground fault condition occurs the ke...

Page 9: ... FOR SERVICE appears in some keypad displays SDI2 keypads display enter Installer Passcode when the pin is locked down On board outputs Terminals 6 and 7 and off board outputs deactivate when the control panel is disabled Terminal 8 has power when the output is deactivated Activation interrupts power at that terminal The on board output Terminal 8 remains deactivated when the reset pin is locked i...

Page 10: ...10 en Installation 2016 07 04 F 01U 291 483 UL Installation Guide Bosch Security Systens Inc Figure 2 3 Reset Pin Callout Description 1 Reset pin locked closed 2 Reset pin normal open ...

Page 11: ...lout Description Callout Description 1 Charging status LED yellow 8 Ring 2 Low battery LED red 9 Operation monitor LED green 3 Color coded battery leads 10 Accessory connector 4 Ground fault detect enable 11 Reset pin 5 Phone LED red 12 SDI interconnect wiring connector 6 Tip 13 SDI2 interconnect wiring connector 7 Telephone cord connector ...

Page 12: ...t D113 Battery Lead Supervision Module 8 To Output A or Output B 2 Batteries 9 Listed Audible Signaling Devices rated at 12 0 VDC nominal do not use vibrating type horns 3 D122 D122L Dual Battery Harness as required 10 C900V2 optional 4 To Supervision Point 11 Secondary phone line part of D928 5 D1640 Transformer NFPA applications may require the use of a D8004 Transformer Enclosure 12 560 Ω 2 W e...

Page 13: ...me might reduce allowable output WARNING Multi Battery installation requires Model D122 or D122L Dual Battery Harness Improper installation can be a fire hazard Battery Replace every 3 to 5 years with one or two Model D126 or D1218 12 V Lead Acid Batteries PROGRAMMABLE ALARM OUTPUTS Terminals SWITCHED AUX and Terminal 8 Operation Monitor LED Pulses when Normal Flickers when Ringing GREEN Point 3 P...

Page 14: ...Guide P N F01U201527 P N F01U201527 for Power Requirements relating to Terminals 6 and 7 CAUTION Refer to the D9412GV4 D7412GV4 Operation and Installation Guide All external connections except Terminal 5 battery positive are inherently power limited Requirements for battery standby time might reduce allowable output WARNING Multi Battery installation requires Model D122 or D122L Dual Battery Harne...

Page 15: ... 8 supervised D1260 Keypads all versions maximum 16 supervised maximum 32 unsupervised 6 ᅳ Zonex 1 15 D8128Ds maximum1 2 ᅳ Up to 8 D9210C Access Control Interface Modules 7ᅳ Zonex 2 15 D8128Ds maximum1 3 ᅳ Up to 2 B450 B426 B420 DX4020 or ITS DX4020 G communication modules 8 ᅳ Zonex 1 Up to 8 D129s maximum1 4 ᅳ D8125 POPEX Module 9 ᅳ Zonex 2 Up to 8 D8129s maximum1 5 ᅳ Up to 119 D9127U T POPITs 1 ...

Page 16: ...upervised D1255 all versions D1255RB D1256RB Keypads D1257RB Fire Annunciators D1265 or up to 8 supervised D1260 Keypads all versions maximum 16 supervised maximum 32 unsupervised 2 Up to 2 D9210C Access Control Interface Modules 3 Up to 2 B450 B426 B420 DX4020 or ITS DX4020 G communication modules 4 D8125 POPEX Module 5 Up to 67 D9127U T POPITs 6 Zonex 1 Up to 9 D8128Ds maximum 7 Zonex 1 Up to 8 ...

Page 17: ...Modules1 2 B308 Octo output Modules1 3 B420 communication modules B426 or B4501 4 B810 wireless receiver or B820 SDI2 Inovonics Interface Modules1 5 B915 Basic Keypad B920 Two line Alphanumeric Keypad B921C Two line Capacitive Keypad with Inputs1 6 B930 ATM Style Alphanumeric Keypad B942 B942W Touch Screen Keypad1 7 B520 Auxiliary Power Supply Module1 1 Refer to the table below for information on ...

Page 18: ...ly 5 inputs are available on the Octo input at address 7 2 For the D7412GV4 only 4 outputs are available on the Octo output at address 6 3 For the B450 B426 B420 only two devices can be installed at one time 4 For the B810 and B820 wireless receivers only one device can be installed either B810 or B820 receiver at one time 5 For the B915 B920 B921C B930 or B942 B942W a total of 16 keypads in any c...

Page 19: ...llout ᅳ Description 1 ᅳ Control panel 2 ᅳ SDI2 module 3 ᅳ Daisy chained wiring 4 ᅳ Single level T tapped wiring 5 ᅳ Home run wiring If the voltage at any device is below the minimum you must add an auxiliary power supply to the system to power these devices Notice The absolute lowest voltage for the SDI2 devices is 10 VDC at the device terminals when in normal operation with a fully charged batter...

Page 20: ... 19 7350 24 5800 29 4828 34 4100 20 7000 25 5600 30 4700 35 4000 21 6666 26 5385 31 4516 36 3800 Table 3 2 Maximum cable length Notice Use Non shielded cable only Notice Maximum capacitance of 140nF 140 000 pf per system Contact the wire manufacturer for the capacitance ratings of the wire being used 3 6 Keyswitch Wiring Figure 3 12 Keyswitch Wiring Callout Description 1 Maintained keyswitch 2 Mom...

Page 21: ...Diagrams en 21 Bosch Security Systens Inc UL Installation Guide 2016 07 04 F 01U 291 483 Use proper EOL for the specific device you are using ...

Page 22: ...me and UL 864 requirements Reference the table below to view the Modem4 communication format signals Modem4 Events Modem4 code D6500 Mode Modem4 Code Bosch SIA Mode Contact ID Events Contact ID Codes AC Fail mains power supply Pssss NAT AC Loss 1 301 00 000 AC Restore mains power supply Rsss0 NAR AC Loss 3 301 00 000 Table 4 3 AC Power Fail 4 1 2 Installing the Transformer Notice Do not short circ...

Page 23: ...arallel to the first battery Use a D122 D122L Dual Battery Harness to ensure proper and safe connection Refer to the Standby Battery and Current Rating Chart in the Approved Applications section of the D9412GV4 D7412GV4 v2 02 Installation and System Reference Guide P N F01U265457 for battery standby time calculations D1218 Battery The D1218 is a 12 V 18 Ah battery for use in applications requiring...

Page 24: ...d Terminal 5 Always disconnect the positive red lead from the battery before removing it from Terminal 5 Warning The battery terminals and wire are not power limited A 0 250 in 6 4 mm space must be maintained between the battery terminals battery wiring and all other wiring Battery wiring cannot share the same conduit conduit fittings or conduit knock outs with other wiring Refer to the Battery Te...

Page 25: ...ay output wires 5 ᅳ Input or Zone wires 6 ᅳ Standby battery 4 3 Power Outputs Circuit Protection 5 PTC s protect the control panel from short circuits on the continuous and programmable power outputs The PTC assignments are listed below PTC CB2 protects Terminal 3 Auxiliary Power PTC CB4 protects Terminal 6 Output A Alarm Power Output Terminal 7 Output B Alternate Alarm Power Output Terminal 8 Out...

Page 26: ...s terminal to power serial device interface 2 SDI2 devices such as B208 B308 B426 B810 B920 B930 and other compatible SDI2 devices 4 5 Power Outputs Continuous Power Output Terminals 3 8 24 32 and 36 The continuous current draw for powered devices connected to Terminals 3 8 24 32 and 36 and the accessory connector must not exceed 1 4 A Devices powered from these outputs must operate at 12 0 VDC No...

Page 27: ...es the 1 4 A of primary power produced by the power supply with the secondary power source the battery to produce a total of 2 0 A of alarm power at 12 0 VDC Nominal Terminals 6 and 7 share the available alarm power Power Restricted for Fire and Combined Fire and Burglary Systems Fire systems are prohibited from using the battery for determining alarm power Use the fire system power formula descri...

Page 28: ... verification and reset output Refer to Output Parameters and Point Assignments in the D9412GV4 D7412GV4 v2 02 Program Entry Guide P N F01U265459 for instructions on programming verification reset outputs and points Performing a sensor reset at a keypad produces a five sec activation of reset outputs The control panel ignores verification and reset points during the five sec activation ...

Page 29: ...6 1 4 A maximum at 12 0 VDC Nominal continuous supply total for all devices and outputs supplied at Terminals 3 24 32 and 36 Alarm Power Output Terminals 6 and 7 2 0 A maximum at 12 0 VDC Nominal output Output can be steady or one of four pulsed patterns depending on programming Refer to Outputs in RPS Help Switched Aux Power Terminal 8 1 4 A maximum at 12 0 VDC Nominal output Continuous output is...

Page 30: ...on 10 2 VDC Minimum operational voltage 10 0 VDC Battery load shed Recharge Cycle AC ON Load shed relay resets battery charging begins Battery Trouble and AC Restoral Reports sent 13 7 VDC Battery Restoral Report sent Low Battery LED off 13 9 VDC Charging status LED off battery float charged Environmental Temperature 32゚F to 120゚F 0゚C to 49゚C Relative Humidity Maximum 93 non condensing Arming Stat...

Page 31: ...All external connections are power limited except battery terminals Continuous Power Outputs SDI2 Out AUX PWR terminals rated range 2 0 A maximum at 11 5 to 12 2 VDC special application continuous supply total for all devices and outputs supplied at Terminals 1 4 6 36 Fire and Fire Burglary Systems To comply with UL 985 and 864 listing standards for fire alarm systems the total combined continuous...

Page 32: ...equires B12 mounting plate AE1 AE2 Enclosures Tab 5 4 B520 Specifications 5 2 Terminal Wiring Requirements Terminal No Terminal Description Requirements 1 AC 18 AWG min up to 14 AWG max 2 AC 18 AWG min up to 14 AWG max 3 AUX POWER Terminal accommodates 14 to 22 AWG use appropriate wire size based on current 4 BATTERY Bosch supplied wire lead included with panel 5 BATTERY Bosch supplied wire lead i...

Page 33: ...appropriate wire size based on loop resistance less than 100 Ω 20 POINT 7 Terminal accommodates 14 to 22 AWG use appropriate wire size based on loop resistance less than 100 Ω 21 POINT 7 8 COMMON Terminal accommodates 14 to 22 AWG use appropriate wire size based on loop resistance less than 100 Ω 22 POINT 8 Terminal accommodates 14 to 22 AWG use appropriate wire size based on loop resistance less ...

Page 34: ... UL 864 UL 985 Intrusion cUL Intrusion B208 Octo input Module X X X X B308 Octo output Module X X X X B426 B420 Conettix Ethernet Communication Module X X X X B4405 Plug in Cellular Communicator using 3G X X X B4415 Plug in Cellular Communicator using CDMA X X X B442 Plug in Cellular Communicator1 6 using GPRS X X X X B443 Plug in Cellular Communicator1 6 using HSPA X X X X B450 Plug in Communicat...

Page 35: ...X X D1257RB Fire Alarm Annunciator X X X X D1218 12 V 17 2 Ah Rechargeable Battery D1255 D1255B Keypads General Purpose X X X D1255W Text Keypad white X X X D1260 D1260B2 Keypads X X X D1640 16 5 VAC 40 VA Transformer X X X D1640 CA 16 4 VAC 40 VA Transformer for Canada X D8004 Transformer Enclosure X X X D8125 POPEX Module X X X X D8125MUX Multiplex Bus Interface X X X D8128D OctoPOPIT Module X X...

Page 36: ... SB A3 RADION panic X RFKF TB A3 RADION keyfob X RFKF FB A3 RADION keyfob X 1 Where the fire alarm transmitter is sharing on premise communications equipment the shared equipment must be UL Listed ITE or fire protective signaling 2 Version 1 04 or above 3 Compatible with version 2 xx or higher 4 Refer to Two Wire Smoke Detectors section in the Approved Applications chapter in the D9412GV4 D7412GV4...

Page 37: ... Security Systens Inc UL Installation Guide 2016 07 04 F 01U 291 483 Notification Appliance Circuit NAC The control panels do not have an onboard NAC A D192G can be added to the control panel or D8129 B308 and is Class B Style W ...

Page 38: ......

Page 39: ......

Page 40: ...Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 USA www boschsecurity com Bosch Security Systems Inc 2016 Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany ...

Reviews: