12.0 Programmer/Accessory Connections
Figure 30: Reset Pin
Reset Pin
Disable All Except Battery
Charging And Programming
PERIPHERAL DEVICE CONNECTIONS
RED
POWER +
YELLOW
DATA BUS A
GREEN
DATA BUS B
BLACK
COMMON
32
31
30
29
2
1
1 - Reset Pin locked (closed)
2 - Rest Pin normal (open) for normal panel operation
Figure 31: Programmer and Accessory Connections
1 - Accessory connector
2 - Programming connector
GRN
PROG
CONN
Point 8
GND FAULT
Detect
L
E
D
I
S
A
B
L
E
26
25
NEX IN 2
NEX POWER +
24
ZONEX COMMON
23
2
1
12.0 Programmer/Accessory
Connections
12.1
Programmer Connector
Refer to the D5200 Operation Manual for complete
information on using the D5200 programmer.
To connect and disconnect the programmer:
1.
Lock the Reset Pin (see Figure 30).
2. Connect the D5200 Data/Power cord into the
programmer connector.
3. Perform the desired programming function (send or
receive program).
4. Disconnect the programmer.
12.1.1
Programmer Access Reports
When a program is sent to the panel, the panel sends a
Prog Access OK Report 10 seconds after the handler
exits or when the programmer disconnects. The prompt
in routing must be programmed
YES
to send this
report.
12.2
Accessory Connector
Use the accessory connector to connect the panel to the
D928 Dual Phone Line Switcher. The accessory
connector is on the bottom right corner of the I/O
board (see Figure 31). The D928 lets the panel use two
telephone lines to transmit reports.
See Section 6.12 D928 Dual Phone Line Switcher for
installation and operating instructions.