D9412G/D7412G
| Operation & Installation Guide |
2.2
Specifications
2.0 Overview
Voltage Input*
(Power Supply)
Primary:
16.5 VAC 40 VA class 2 plug-in transformer (D1640)
Secondary:
Sealed lead-acid rechargeable battery (12 VDC, 7 Ah or 12 VDC, 17.2 or
18 Ah). The panel supports a maximum of two 12 VDC, 7 Ah batteries
using the D122 Dual Battery Harness or two D1218 (12 VDC, 17.2 or 18
Ah) batteries using a D122.
Current
Requirements
Panel : 500 mA alarm, 200 mA idle
See Section 4.1 Current Rating Chart for Standby Battery Calculations in the D9412G/D7412G Approved
Applications Compliance Guide
for the current draw requirements of other system components.
Power Outputs*
All external connections are inherently power-limited except battery terminals.
Continuous
Power Outputs
1.4 A maximum at 10.2 VDC to 13.9 VDC (continuous supply) total for all
devices and outputs supplied at Terminals 3, 24, and 32 and at the
Accessory and Programming Connectors.
Alarm Power
Output
2.0 A maximum at 10.2 VDC to 13.9 VDC output. Output may be steady or
one of three pulsed patterns depending on programming. See Relays in the
D9412G/D7412G Program Entry Guide
.
Switched Aux
Power
1.4 A maximum at 10.2 VDC to 13.9 VDC output. Continuous output is
interrupted by Sensor Reset or alarm verification depending on
programming. See Relays in the D9412G/D7412G Program Entry Guide.
Fire and
Fire/Burglary
Systems
To comply with UL 985 and 864 listing standards for fire alarm systems (effective March 1,
1989), the total combined continuous and alarm current draw for the system during alarm
conditions must be limited to 1.4 A (1400 mA) provided by the primary power supply (rectified
AC). If current draw for the system exceeds 1.4 A, remove connected devices until the current
draw falls below 1.4 A. Then, connect the removed devices to a D8132 Battery Charger
Module or to an external power supply (see Figure 26).
Minimum
Operating
Voltage
10.2 VDC
SDI Bus
SDI Bus A (+):
SDI Bus B (-):
9 VDC 4572 m (15000 ft.) maximum
9 VDC 4572 m (15000 ft.) maximum
Telephone
Connections
Connection:
Two TelCo
Lines:
RJ31X
or
RJ38X jack can be interfaced with the panels.
Bosch Security Systems D928 Dual Phone Line Module required for two phone line service.
Supervision supplied by the panel.
Battery
Discharge/
Recharge
Schedule
Discharge
Cycle
13.9 VDC
13.8 VDC
12.1 VDC
10.2 VDC
Charging float level.
Charging status LED on.
Low Battery and AC Fail Reports if programmed. Low Battery LED on.
Battery load shed (processing functions continue if AC is present).
Recharge
Cycle
AC ON
13.7 VDC
13.9 VDC
Load shed relay resets, battery charging begins, Battery Trouble and AC
Restoral Reports sent.
Battery Restoral Report sent, Low Battery LED off.
Charging status LED off, battery float charged.
Environmental
Temperature:
Relative
Humidity:
0°C to +50°C (+32°F to +122°F)
5% to 85% at +30°C (+86°F) non-condensing
Arming
Stations
D720 Command Center, D1255 Command Center, D1256 Fire Command Center; D1257 Fire Alarm
Annunciator; D1260 Alpha V Command Center; Keyswitch
Point
Thresholds
On-board
Points 1 to 8
Open
Normal
Short
Greater than 3.7 VDC, but less than 5.0 VDC.
Greater than 2.0 VDC, but less than 3.0 VDC.
Greater than 0.0 VDC, but less than 1.3 VDC.
Compatible
Enclosures
D8103 Universal Enclosure, D8109 Fire Enclosure, D8108A Attack Resistant Enclosure
*The black and white circles with numbers indicate the specific panel terminal.
Table 5: Specifications