6 720 808 869 (2014/06)
Compress 3000 DW FOO
Appliance status information | 33
5.7.4 „PLUS“ - enhanced comfort function
The "PLUS" is a comfort function which is factory set to be
active but can be deactivated.
This function enables the appliance to automatically switch on
the electrical heater together with the heat pump cycle when
the air temperature is below 10 °C, the water temperature at
the bottom is cold, and a rapid temperature decrease at the top
of the tank is detected. Hence, by activating the auto boost, the
appliance will initiate a fast recover at the top of the tank to face
a potential lack of hot water. Once a hot water buffer is created
at the top, the appliance will proceed the recover by using the
heat pump cycle only.
Fig. 40
„PLUS“ function
To deactivate/activate the „PLUS“ function
▶ Access „PLUS“ function and press „ok“.
▶ Use "+" and "-" keys to select "on" or "off" and press "ok" to
confirm selection.
▶ Press "menu" to exit.
"PLUS" is displayed.
5.7.5 „HEA“ - heating by electrical assistance
The „HEA“ function is only available in case of malfunctioning of
the heat pump cycle and requires technical assistance
guidance.
Fig. 41
„HEA“ function
5.7.6 „Purg“ function - purge
„Purg“ function is an auxiliary feature for the system purging
process.
Fig. 42
„Purg“ function
To activate „Purg“ function
▶ Access „Purg“ function and press „ok“. The circulation
pump will start functioning and the timetable is displayed
below "Purg". After 5 minutes the appliance returns to the
normal operation according to the settings previously
selected.
After the LEG cycle has concluded, it is
possible that the appliance will starts
operating even though the temperature
displayed is above the selected set point.
This is an advanced comfort feature
incorporated in to the appliance to heat up
only the lower part of the tank (if required).
Therefore, this feature ensures a quick
temperature recovery for the lower half of
the storage tank when hot water is tapped
after a legionella disinfection cycle and the
top of the tank remains around the set point.
6720807918-03.1V
During the period the "Purg" function is
active, the display shows the remaining time
(minutes) until the procedure is completed
.
6720807918-04.1V
6720801967-02.1V