9.3.2 Removing the fan assembly
1. Follow steps outlined in Section 9.3.1.
2. Remove the nut
À
xing the fan and remove the fan.
Figure 135
3. Un
À
x the hooks and then open the electronic control box cover.
Figure 136
4. Disconnect the fan motor, connector CN19.
Figure 137
5. Remove the four
À
xing screws of the fan motor, then remove the motor.
Figure 138
9.3.3 Removing the electrical parts
1. Follow steps outlined in Section 9.3.1.
2. Pull out connectors of reactor, compressor and PFC inductor.
Figure 139
3. Disconnect CN53, CN54 and CN55 connectors from driver board and PCB.
Figure 140
CN53
CN54
CN55