Service Manual
Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Multi Zone Outdoor Units
| 23
Bosch Thermotechnology Corp.
|
08.2020
Data subject to change
8.1 Multi Zone Outdoor Unit Error Codes
NOTICE
f
If below error codes appear, please turn off the system and
contact an Authorized Service Provider.
ODU Display
Possible Causes
Indoor Display
E0
Outdoor unit EEPROM parameter error
F4
E2
Communication malfunction between indoor and outdoor units
E1
E3
Communication malfunction between IPM board and outdoor main control board
——
E4
Outdoor temperature sensor (coil sensor T3, ambient sensor T4, Compressor
discharge sensor T5, indoor coil outlet pipe sensor T2B) malfunction
F2/F1/F3/F6
E5
Over-voltage or under-voltage protection
P1
E6
PFC module protection
——
E8
Outdoor fan speed malfunction
F5
F1
No. A Indoor unit coil outlet temp. sensor malfunction
——
F2
No. B Indoor unit coil outlet temp. sensor malfunction
——
F3
No. C Indoor unit coil outlet temp. sensor malfunction
——
F4
No. D Indoor unit coil outlet temp. sensor malfunction
——
F5
No. E Indoor unit coil outlet temp. sensor malfunction
——
F6
No. F Indoor unit coil outlet temp. sensor malfunction
——
P0
High temperature protection: top of compressor
P2
P1
High pressure protection
P6
P2
Low pressure protection
P6
P3
Current overload protection
F0
P4
Temperature protection of compressor discharge
——
P5
Condenser high temperature protection
——
P6
Inverter module (IPM) malfunction
P0
LP
Low ambient temperature protection
——
Table 15
For Indoor Error Codes, please refer to the indoor service manual.