NOTE:
If installing the fiber optic version, bring video coax
and fiber optic cable into the box and connect as shown in
PHOTO 5C. Philips’ LTC 4629 Fiber Transceiver is required at
head end system.
ν
Optical Fiber Compatibility: 50/125 mm, 62.5/125 mm, low
loss multimode glass fiber, rated for a minimum
system bandwidth of 20 MHz (video 850 nm/control 1300
nm)
ν
Maximum Distance: 4 km (2.5 miles)
NOTE:
Inspect the enclosure fittings after installation to
ensure that the gaskets have not been damaged, replacing as
necessary.
Photo 5C Interior View of ENV-PSU1F
Photo 5D Power Supply Enclosure
Photo 5E Power Supply Board
5.3
Mounting of Pipe and Roof (Parapet) Mounts
5.3.1
LTC 9543/00 Pipe Mount
5.3.1.1 TOP-MOUNTING FLANGE
Included with the Pipe Mount is a top-mounting flange. If
this flange is to be used, be sure it is secured to the ceiling (or
other supporting structure) using a minimum of four (4) 10
mm (
3
⁄
8
-inch) diameter fasteners.
NOTE:
For safety purposes, each fastener should have a mini-
mum of 275 kg (600 lbs) pullout strength. If the unit is exposed
to the
elements, use the supplied gasket between the flange and the
structure.
All wiring must be run through the center of the flange.
Ensure there is an adequate opening in the ceiling (or mounting
structure) for this purpose.
5.3.1.2 CONNECTING PIPE TO STRUCTURE
Once the flange is mounted, run the wires through the flange
and into the pipe.
Apply Teflon Tape (provided) to the pipe threads, then thread
the pipe into the flange.
Proceed to SECTION 5.4, ATTACHING THE DOME.
5.3.2
LTC 9230/00 Roof (Parapet) Mount
NOTE:
For Wind Loading specifications, refer to the
LTC 9230/00,
LTC 9230/01 PARAPET MOUNTS
INSTALLATION INSTRUCTIONS, SECTION 7.1.
5.3.2.1 MOUNTING HARDWARE
Mounting hardware has not been included, as it must be
selected to work with the type of wall to which the unit will
be mounted.
Installation
EN
© 2003 Bosch Security Systems
Page 15 of 24
Mains Power
Green
Ground Screw
Connect Signal &
Power to Camera
Video Out to head
out or Fiber Board
Control Signal from
Head End
Fiber Connection
Video In
from
Camera
Power (Out to Camera)
Control In & Out
Power In
Heater Fuse
Mains
Power Fuse
Power Input
Power & Control
to Camera
Earth Ground