background image

AMC2 4W

APC-AMC2-4W | APC-AMC2-4WCF | APC-AMC2-4WUS 

en

Installation manual

Summary of Contents for APC-AMC2-4W

Page 1: ...AMC2 4W APC AMC2 4W APC AMC2 4WCF APC AMC2 4WUS en Installation manual ...

Page 2: ......

Page 3: ...ties or limitation of liability for incidental or consequen tial damages so the above limitation or exclusion might not apply to you Bosch Security Systems retains all rights not expressly granted Nothing in this license constitutes a waiver of Bosch s rights under the U S Copyright laws or any other federal or state law If you have any questions concerning this license please write to Bosch Acces...

Page 4: ...ration 15 3 3 Performance Characteristics 18 3 4 System Overview 19 4 Technical Data 20 5 Installing 22 5 1 Mounting 22 5 2 Demounting 23 5 3 Opening the AMC2 4W Case 24 5 4 Cabling 25 5 4 1 Conductor data for connection to power supply 25 5 4 2 Grounding and Shielding the Host Interface 26 5 4 3 Grounding and Shielding the Extension Interface 28 5 5 Connecting Power Supply 28 5 6 RS 485 Host Inte...

Page 5: ...11 Connecting Relay Outputs 41 5 12 Connecting Analog Input Devices 44 5 13 Tamper Protection 46 6 Operating 48 6 1 Status Display of the AMC2 4W 48 6 2 Configuring the Ethernet Interface 50 6 3 Resetting the AMC2 4W 50 6 3 1 Resetting the Software 50 6 3 2 Resetting the Network Configurations 51 7 Appendix 53 7 1 Connecting Diagrams 53 7 2 Legend 57 8 Index 58 ...

Page 6: ...6 en AMC2 4W F 01U 024 965 V 4 2006 09 Installation manual Bosch Security Systems ...

Page 7: ...o keep in mind These appear different from the rest of the text as fol lows 1 2 Internet If you are interested in further information on this product or information on other products please refer to our website at http www bosch security systems com CAUTION or WARNING These warn the operator that damage to the program or equip ment might occur i NOTE Important Notes must be followed for successful...

Page 8: ...rious injury to persons and damage to the unit Mount the unit according to the manufacturer s instructions 5 Service Do not attempt to service this unit by yourself Opening or removing covers may expose you to dangerous voltages or other hazards Refer all servicing to qualified service personnel 6 Damage Requiring Service Disconnect the unit from the main AC or DC power source and refer servicing ...

Page 9: ... source indicated on the label If unsure of the type of power supply to use contact your dealer For units intended to operate from battery power refer to the operating instructions For units intended to operate with External Power Supplies use only the recommended approved power supplies For units intended to operate with a limited power source this power source must comply with EN UL 60950 Substi...

Page 10: ...dental installation This equipment generates uses and can radiate radio fre quency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio com munications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be ...

Page 11: ... damaging equipment Always switch off power of the AMC2 4W before mod ifying the installation Do not connect or disconnect plug connectors data cables or screw connectors while power is on Health and Safety Installation of the AMC2 4W must comply with any local fire health and safety regulations A secured door that may be part of an escape route from an area must be installed with A fail safe lock...

Page 12: ...a Bosch Security Systems salesperson The shipping car ton is the safest transport container for the unit Store it and the other packaging material for future use If the unit has to be sent back use the original packaging CAUTION Disconnect both AC and battery power supply before working on the controller Warning Risk of damage Protect the hardware from electrostatic discharge by observing ESD inst...

Page 13: ... is stored in a battery buffered on board memory and a Compact Flash CF memory card This guarantees autonomous access decisions and complete access registrations even if the management host system is offline The built in compact flash adapter provides adequate storage capability for cardholders and events The AMC2 4W electronic is completely covered by a plastic housing The LC Display provides all...

Page 14: ...ck mechanisms if access is granted or acti vate an external alarm system if an intrusion or system alert is detected If the eight input and output on board are not enough to configure the system up to three additional extensions AMC2 8I 8O EXT or AMC2 16I 16O EXT can be connected The extensions offer 8 or 16 additional inputs and outputs The setup procedure for an AMC2 4W is very simple and extrem...

Page 15: ... replaced by qualified per sonnel every ten years or if indicated by an appropriate event 4 Reset push button available by using the srew driver 5 LC Display 6 Push button to select the display view available by using the push button on the top of the housing 7 Jumper Potential equalization between different mass sys tems and protective earth shield 8 Jumper interface selector RS 485 Host connecti...

Page 16: ...et interface Fig 3 4 Overview Interfaces 13 RS 485 extension module bus Pluggable screw connector 14 External tamper contact Pluggable screw connector 15 Power supply Pluggable screw connector 16 Wiegand interfaces for up to 4 card readers Pluggable screw connector 17 Connectors for eight analog inputs Pluggable screw con nector 18 Connectors for eight relay outputs Pluggable screw con nector ...

Page 17: ...V 4 2006 09 Fig 3 5 Jumper at the bottom side 19 Jumper Selector for either potential free relay output or powered by AMC2 4W internal power supply wet dry con tacts 20 Jumper Potential equalization between different mass systems and protective earth shield for the extension interface ...

Page 18: ...t relay outputs potential free or with internal power supply Eight analog inputs with internal power supply Battery buffered SRAM and real time clock RTC Pluggable Compact Flash from 64 MB to 1024 MB LC Display Transfer rate host interface RS 485 38 4 kBit s Transfer rate host interface RS 232 38 4 kBit s Transfer rate host interface Ethernet 10 100 Mbit s Self controlling transfer receive switchi...

Page 19: ...nnection via RS 485 or RS 232 is also pos sible Fig 3 6 System overview The number of controllers in one system is limited to 200 Corresponding to the available interfaces one AMC can be con nected to each COM Port using RS 232 mode In RS 485 mode up to eight access controllers can be combined on one party line Via Wiegand interfaces up to four peripheral devices can be connected to each AMC2 4W T...

Page 20: ...L sliding switch or software Host interface RS 485 2 wire or 4 wire Transfer rate 38 4 kBit s No parity 8 Bit 1 Stopbit RS 232 Transfer rate 38 4 kBit s No parity 8 Bit 1 Stopbit Ethernet 10 100 Mbit s Four Wiegand interfaces for card readers Eight relay outputs max switching power 37 5VA max switching voltage 30V DC max switching current 1 25A Eight analog inputs with sabotage monitor ing Tamper ...

Page 21: ...d 25VA Connectors Pluggable screw connectors Protection Class IP30 Environment temperature 0 C to 45 C Humidity Up to 95 without condensation Housing mate rial ABS with OC UL 94 V 0 Dimensions W H D 232mm x 90mm x 63mm 8 9 x 3 5 x 2 4 in Weight app 0 53 kg 0 9 pounds CAUTION The voltage drop from the power supply to the AMC has effect on the AMC Interfaces Their sum shall be less than 2V ...

Page 22: ...ling 5 1 Mounting The AMC2 4W can be attached on a standard 35 mm 1 377 in mounting rail via a snap in mechanism Attach the AMC2 4W into the upper edge of the mounting rail then push down the AMC2 4W and snap it onto the rail by pushing it towards the back Fig 5 1 Mounting the AMC2 4W on a mounting rail ...

Page 23: ...2006 09 5 2 Demounting Push down the AMC2 4W until it snaps out of the mounting rail Pull the lower end of the AMC2 4W from the mounting rail Fig 5 2 Demounting the AMC2 4W from a mounting rail i NOTE To remove the AMC2 4W from a mounting rail first remove all pluggable screw connectors ...

Page 24: ...W case consists of a top cover mounted with a two point snap in closure on a ground chassis To open the AMC2 4W push down the two snap ins with a srew driver After that the cover can be moved to bottom Fig 5 3 Opening the AMC2 4W case i NOTE To open the AMC2 4W first remove all pluggable screw con nectors at least the host connection ...

Page 25: ...ort distances below 25m 75 feet use AWG18 conduc tors For higher distances install an additional power supply close to the AMC Please calculate the voltage drop by checking the conductor specifications for characteristic resistance values The voltage drop shall not exceed 2V Example Length 100m 328 ft CAUTION The cables used in the AMC2 4W access control system are not prone to electrical interfer...

Page 26: ...Critical condition Install the power supply closer to the con troller 5 4 2 Grounding and Shielding the Host Interface Fig 5 4 Location of ground jumper RS 485 host interface The jumper setting A1 shows the delivery status ft 1000 385 6 Ω km Ω km Ω ft 1000 385 6 Ω i NOTE These specifications aim for readers relay outputs and exten sions For inputs there are other value to keep in mind see therefor...

Page 27: ...d conductor and the shield on the host are not con nected and no partyline exists the jumper JP2 is set A3 a partyline exists and PAG is connected the jumper JP2 is set at the first device only A3 a partyline exists and PAG is not connected the jumper JP2 is set at all devices A3 i NOTE Generally the following counts If the devices have an own power supply the shield will be connected on one point...

Page 28: ...nternal ground of the AMC2 4W to the RS 485 ground of the slave interface Jumper B shall only be set B2 if the AMC2 4W powers all other peripheral devices which are directly connected to the AMC2 4W 5 5 Connecting Power Supply Connect the power supply to the 7 pin pluggable screw connec tor labeled with POWER on the upper case i NOTE A complete connection diagram of the power supply connector is s...

Page 29: ...gative of the pluggable screw connector When using a shared 12V DC power supply for internal electron ics and peripherals pin 1 and pin 6 resp pin 3 and pin 7 can be shortened If an uninterruptible power supply UPS is used the relay out put for power good signals from the UPS is connected to the following pins pin 4 and 7 for power good AC pin 5 and 7 for power good Battery pin 6 and 7 for power g...

Page 30: ...965 V 4 2006 09 Installation manual Bosch Security Systems 5 6 RS 485 Host Interface An RS 485 host system can consist of up to eight AMC2 4W controllers connected via 2 or 4 wire connection Fig 5 7 Configuration of a RS 485 host system ...

Page 31: ... eight AMC2 4W The maximum number of devices must not be exceeded For longer bus lines connect the AMC2 4W to multiple AMC MUX EXT with the host To use RS 485 mode at the AMC2 4W connect the data cables to the pluggable screw connector of the RS 485 host interface Set the connection mode of the RS 485 using the DIL switch of the AMC MUX Then set the RS 485 address via DIL switch or software and ac...

Page 32: ...Installing AMC2 4W F 01U 024 965 V 4 2006 09 Installation manual Bosch Security Systems Fig 5 8 RS 485 host interface 5 6 1 RS 485 Two Wire Connection Fig 5 9 Connection scheme of a RS 485 two wire connection ...

Page 33: ... the AMC MUX DIL Switch at the position 3 7 and 8 to ON On the upper side of the AMC panel put the jumper on the two pins on the right hand side of the connector 8 see also Figure 3 3 Set the RS 485 address of the AMC using the DIL Switch see Section 5 6 3 DIL Switch Address Selector 5 6 2 RS 485 Four Wire Connection Fig 5 11 Connection scheme of an RS 485 four wire connection ...

Page 34: ...e connector 8 see also Figure 3 3 Set the RS 485 address of the AMC using the DIL Switch see Section 5 6 3 DIL Switch Address Selector 5 6 3 DIL Switch Address Selector The first four DIL switches for address selection define the RS 485 address of the AMC2 4Win a RS 485 bus system Switch 5 selects on of the two different protocols SDEB and BPA according to DIN6619 Switch 6 sets the connection to t...

Page 35: ...85 address selector i NOTE Using Ethernet connection it is recommended to set switch 1 to ON delivery status Using RS 232 connection the address must be set which is con figured in the Device Editor Therefore this is a point to point connection the usually configured address will be 1 so the switch 1 must be also set to ON ...

Page 36: ...DIL Switches 1 2 3 4 none OFF OFF OFF OFF 1 ON OFF OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON Table 5 1 Setting the RS 485 address with the DIL switch Mode DIL Switches 5 6 ON SDEB RS 232 OFF BPA RS 485 Table 5 2 Protocol and connection settings CAUTION Cable length between two RS 232 COM serial interfaces must not exce...

Page 37: ...able for example 5 8 Ethernet Interface The AMC2 4W offers an additional 10 100 Mbit s Ethernet auto sensing interface to connect to a local area network or host computer i NOTE A complete connection diagram of the RS 232 host interface is shown in Figure 7 3 CAUTION Use either a CAT5 crossover cable to connect the AMC2 4W directly to a computer s network interface or a standard CAT5 patch cable t...

Page 38: ...DHCP it can take several time if the AMC is known on the remote server This cause in the DNS cache of the lokal PC it will be refreshed only after special duration To speed up this procedure give in the following command in a command prompt ipconfig flushdns After this the AMC should be available by its name i NOTE A complete connection diagram of the Ethernet host interface is shown in Figure 7 4...

Page 39: ...ide additional in and outputs for example for elevator con trol You can find further information about the extension boards in the installation manual of these modules Order no F 01U 024 967 Fig 5 16 Location of the RS 485 extension module bus 5 10 Wiegand Interface for Card Readers The AMC2 4W has four Wiegand interfaces to integrate up to four card readers with Wiegand compatible interfaces Each...

Page 40: ...14 and S19 Fig 5 17 Location of the Wiegand interfaces for external devices The interfaces are point to point connections You can connect only one reader to an interface the cable length is limited to 150 m 492 ft Like the numbering of the interfaces the reader get their address i NOTE A complete connection diagram of the Wiegand interface is shown in Figure 7 7 ...

Page 41: ...ght form C relay outputs The outputs will be connected to the 3 pin pluggable screw connectors S5 S6 S10 S11 S17 S18 S22 and S23 see Figure 7 5 Fig 5 18 Location of the relay output connectors Each relay output can operate in wet mode using the AMC2 4W s internal 12V DC power supply for external devices or dry mode with potential free contacts for externally pow ered systems ...

Page 42: ...s have to be short circuited using recovery diodes see Figure 5 20 These diodes BAX12A are sup plied with every AMC2 4W package If you need higher voltage for special constructions you can connect external relays to the outputs Recommended depending on the power supply mode are the relay types of the company Wieland Flare move 12DC1W10A Flare move 24DC1W16A But you can also use products of manufac...

Page 43: ... recovery diode Each relay output has a separate jumper setting on the bottom side of the lower circuit board to activate wet D2 or dry D1 mode Risk of Damage Do not connect externally powered devices in wet mode This can damage the AMC2 4W i NOTE A complete connection diagram of the relay output connectors is shown in Figure 7 9 ...

Page 44: ...of relay output jumpers bottom side 5 12 Connecting Analog Input Devices The AMC2 4W has eight analog inputs for example for poten tial free lock mechanisms or to detect if a lock is closed or open The inputs will be connected to the 2 pin pluggable screw connectors S3 S4 S8 S9 S15 S16 S20 and S21 see Figure 7 5 ...

Page 45: ...ppropriate devices are connected 1 Door open RS RP 2 Door closed RS 3 Broken wire RS RP 4 Short circuit RS RP 0 The resistor values can vary and depend on the used lock system wire resistance negligible The AMC2 4W package includes 2 2 kΩ resistors using for reserves for the RS and the RP resistor Fig 5 23 Operating modes of a lock using the analog input device i NOTE A complete connection diagram...

Page 46: ...using the tamper contact short circuit the contacts with a wire connection RP 1k 1k2 1k5 2k2 2k7 3k3 3k9 4k7 5k6 6k8 8k2 RS 1k 0 21 0 23 0 26 0 32 1k2 0 20 0 23 0 26 0 32 0 35 1k5 0 20 0 23 0 25 0 32 0 35 0 39 0 41 1k8 0 19 0 21 0 24 0 31 0 34 0 38 0 41 0 44 0 47 0 50 2k2 0 20 0 23 0 30 0 33 0 37 0 40 0 43 0 47 0 50 0 53 2k7 0 18 0 21 0 27 0 31 0 35 0 38 0 41 0 45 0 49 0 51 3k3 0 19 0 24 0 28 0 32...

Page 47: ...AMC2 4W Installing en 47 Bosch Security Systems Installation manual F 01U 024 965 V 4 2006 09 Fig 5 24 Location of the tamper protection contact ...

Page 48: ... The LC Display delivers information about the AMC2 4W status Push the Dialog button to switch between different modes Fig 6 1 Location of the Dialog button The display mode which has been set remains until the next operation of the Dialog button The order of the display pages is determined and follows the scheme shown in the table below ...

Page 49: ...Display of the digital contacts setted input signals will be shown with an extension above output signal with an extension below 3a Dig I1 If there are I O Boards con nected the signals will be shown on separate pages 3b Dig I2 3c Dig I3 4 MAC 0010174C8A0C MAC address 5 N AMC 1234 5678 Network name of the AMC 6 I 192 168 10 18 IP address of the AMC 7 H 192 168 10 10 IP address of the host computer...

Page 50: ...problem occurs first try to fix the problem directly If this does not solve the problem resetting the AMC2 4W may help 6 3 1 Resetting the Software 1 Insert the provided screwdriver into the hole as shown in the figure below 2 Push the reset button for at least three seconds 3 The AMC2 4W will be reset and reboots You are back in the download program Now it is possible to reconfigure the AMC2 4W f...

Page 51: ...e Network Configurations 1 Reset the AMC2 4W as described above in download pro gram 2 Open the upper case of the AMC2 4W as described in Section 5 3 Opening the AMC2 4W Case 3 Set all six DIL switches of the RS 485 selector to ON 4 Press the tamper switch on the upper left side of the board The AMC2 4W will now have the following network configura tion DHCP 0 IP 127 0 0 1 ...

Page 52: ...52 en Operating AMC2 4W F 01U 024 965 V 4 2006 09 Installation manual Bosch Security Systems Fig 6 3 Resetting the AMC2 4W to delivery state ...

Page 53: ...AMC2 4W Appendix en 53 Bosch Security Systems Installation manual F 01U 024 965 V 4 2006 09 7 Appendix 7 1 Connecting Diagrams Fig 7 1 Connectors on upper PCB Fig 7 2 RS 485 host on upper PCB ...

Page 54: ...54 en Appendix AMC2 4W F 01U 024 965 V 4 2006 09 Installation manual Bosch Security Systems Fig 7 3 Connecting diagram of the RS 232 serial interface Fig 7 4 Ethernet Network socket RJ45 ...

Page 55: ...AMC2 4W Appendix en 55 Bosch Security Systems Installation manual F 01U 024 965 V 4 2006 09 Fig 7 5 Connector blocks of the AMC2 4W ...

Page 56: ...56 en Appendix AMC2 4W F 01U 024 965 V 4 2006 09 Installation manual Bosch Security Systems Fig 7 6 Power supply Fig 7 7 Wiegand interface Fig 7 8 Analog input Fig 7 9 Relay output ...

Page 57: ... 4W Appendix en 57 Bosch Security Systems Installation manual F 01U 024 965 V 4 2006 09 Fig 7 10 Extension interface Fig 7 11 External tamper contact 7 2 Legend Twisted pair connection Transmitter Receiver ...

Page 58: ...tch 34 E Equipment Configuration 15 Ethernet Interface 37 G Grounding 25 I Installing the AMC 4 22 Internet 7 L Legend 57 O Opening the AMC 4 Case 24 Operating the AMC 4 48 P Performance Characteristics 18 Power Supply 28 R Relay Outputs 41 Resetting the AMC 4 50 RS232 Host Interface 36 RS485 Extension Module Bus 39 RS485 Four Wire Connection 33 RS485 Host Interface 30 31 RS485 Two Wire Connection...

Page 59: ......

Page 60: ...Bosch Security Systems Robert Koch Straße 100 D 85521 Ottobrunn Germany Telefon 089 6290 0 Fax 089 6290 1020 www bosch securitysystems com Bosch Security Systems 2006 ...