24
en | Installing
Access Modular Controller 2
2022-03 | V03 |
Installation manual
Bosch Security Systems B.V.
i
Notice!
If using an Ethernet connection, set
switch 1
and
5
to
ON
(= delivery status).
Figure 4.14:
Location of the selector for host settings and delivery status
Address
DIP switches
1
2
3
4
none
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
ON
ON
OFF
OFF
4
OFF
OFF
ON
OFF
5
ON
OFF
ON
OFF
6
OFF
ON
ON
OFF
7
ON
ON
ON
OFF
8
OFF
OFF
OFF
ON
Table 4.1:
Setting the address via the DIP switch
Mode
DIP switches
5
6
ON
SDEB
PI
OFF
BPA
RS-485
Table 4.2:
Protocol and connection settings
Host settings
Instructions for DIP switch 5
Set
SDEB
(= DIP switch
5
to
ON
) in the following cases:
–
Ethernet host connection
–
RS-485 host connection, provided only one AMC2 is connected on the bus.
Set
BPA
(= DIP switch
5
to
OFF
) in the case of an:
4
RS-485 host connection with more than one and maximum eight AMC2s per bus.