50
en | Appendices
Access Modular Controller 2
2022-03 | V03 |
Installation manual
Bosch Security Systems B.V.
4
Dig. IO: ::::::::::::::::
Display of the digital contacts: the input signals set will
be shown with an extension above - output signals with
an extension below. The first eight digits display the
controller’s signals. The second eight digits display the
extension board’s signals
4a
Dig. I1: ::::::::::::::::
If there are I/O-Boards connected, the signals will
be shown on separate pages.
4b
Dig. I2: ::::::::::::::::
4c
Dig. I3: ::::::::::::::::
5
MAC 001B860012AB
Network device address (MAC)
6
N AMC-1234-5678
Network name of the controller (max. 14 char.)
See
Configuring Ethernet interface, page 34.
7
I 192.168.10.18
IP-address of the controller
8
G 192.168.10.255
IP-address of the gateway
9
M 255.255.255.0
Subnetmask
10
H 192.168.10.10
IP-address of the host computer
11
DHCP 1
DHCP-status:
1 = on
0 = off
12
D 192.168.10.1
IP-address of the DNS server
13
Host: + "C"
Host activity:
+ = online
- = offline
"C" = Counter (0 to 9) of the received data packages
from the host interface.
RS-485 Bus connection:
A = Address 1 … H = Address 8
14
HSC state: x
Host secure status:
1 = enable
2 = disable
11.2.3
Firrmware xx.61, 37.71
Push
Display (Example)
Description
0
AMC-xxxxx
Display firmware variants:
- Bootloader
- WIEGAND
- LBUS
- OSDP
- BG900
1
Vxx.xx xx.xx.xx
aa = Reader Protocol Version
37 - Wiegand, 60 - Lbus, 61 - BG900, 62 - OSDP
bb = Firmware Version
01.05.17 release date of the firmware (dd.mm.yy)