Access Modular Controller 2
Appendices | en
49
Bosch Security Systems B.V.
Installation manual
2022-03 | V03 |
11.2
Status display
11.2.1
Bootloader V00.49
Push
Display (Example)
Description
0
V00.49 dd.mm.yy
Bootloader version by factory
dd.mm.yy release date of the firmware
1
S/N1: 0910024419
Serial number 18 digits - Part1 10 digits
2
S/N2: 22850034
Part 2 - 8 digits
3
11.18 12:24:18 S
Current date and time (MM.DD hh:mm:ss)
(S) = daylight saving
4
MAC 001B860012AB
Network device address (MAC)
5
N AMC-1234-5678
Network name of the controller (max. 14 char.)
See
Configuring Ethernet interface, page 34.
6
I 192.168.10.18
IP-address of the controller
7
G 192.168.10.255
IP-address of the gateway
8
M 255.255.255.0
Subnetmask
9
H 192.168.10.10
IP-address of the host computer
10
DHCP 1
DHCP-status: 1 = on; 0 = off
11
D 192.168.10.1
IP-address of the DNS server
12
Host: + "C"
Host activity:
+ = online
- = offline
"C" = Counter (0 to 9) of the received data
packages from the host interface.
RS 485 Bus connection:
A = Address 1 … H = Address 8
11.2.2
Firmware until 6x.45, 37.60
Push
Display (Example)
Description
0
Vaa.bb 01.05.17
aa = Reader Protocol Version
37 - Wiegand, 60 - Lbus, 61 - BG900, 62 - OSDP
bb = Firmware Version
01.05.17 release date of the firmware (dd.mm.yy)
1
S/N1: 0910024419
Serial number 18 digits - Part1 10 digits
2
S/N2: 22850034
Part 2 - 8 digits
3
11.18 12:24:18 S
Current date and time (MM.DD hh:mm:ss)
(S) = daylight saving
Summary of Contents for ADS-AMC2-4R4CF
Page 1: ...Access Modular Controller 2 ADS AMC2 4R4CF APC AMC2 4R4CF en Installation manual ...
Page 2: ......
Page 55: ......