![Bosch ACS 500 Series Repair Instructions Download Page 9](http://html.mh-extra.com/html/bosch/acs-500-series/acs-500-series_repair-instructions_44763009.webp)
Robert Bosch GmbH
en
9
ACS 500
1 689 975 197 (2006-09-22)
Error pattern
Cause
Troubleshooting and correction
Compressor will not start.
Power supply interrupted.
Check fuses F2 and F3 on control PCB. Replace defective
fuse.
Check relay on the control printed circuit board. If the re-
lay has blown, replace the control printed circuit board.
White smoke escapes from the
vacuum pump.
Aspirated ambient air.
Inspect the vehicle air conditioning system and ACS for
leaks and repair. Small quantities of smoke in the first min-
utes of the vacuum phase are permitted.