Transport and storage 27/68
RE 93100-01-B/2019-09-10, A20V(L)O Series 1,
Bosch Rexroth AG
An uninstalled axial piston unit must be preserved with corrosion protection for
the duration of storage.
The following instructions only refer to axial piston units operated with
hydraulic fluid on a mineral oil basis. Other hydraulic fluids require other specific
preservation measures. In such a case, consult your local contact person; you can
find their contact information at
www.boschrexroth.com/addresses
Bosch Rexroth recommends the following procedure:
1.
Clean the axial piston unit; see chapter 10.1 "Cleaning and care" on page 54.
2.
Drain the axial piston unit.
3.
For storage times up to 12 months: Moisten the inside of the axial piston unit
with mineral oil and fill with approx. 100 ml mineral oil.
For storage times up to 24 months: Fill the axial piston unit with VCI 329
corrosion protection (20 ml).
Filling is done through the drain port
L
1
,
L
2
,
L
3
, or
L
4
and/or
T
1
or
T
2
and/or
R(L)
1
or
R(L)
2
, see chapter 7.4 "Installing the axial piston unit", Fig. 19 to Fig. 21 on
page 43.
4.
Plug all ports so they are airtight.
5.
Coat unpainted areas of the axial piston unit with mineral oil or suitable,
easily removable corrosion protection, e.g. acid-free grease.
6.
Package the axial piston unit with desiccant in corrosion protection film so it
is airproof.
7.
Store the axial piston unit in a shock-proof manner; see "Requirement"
on page 26 in this chapter.
After removal