IP Camera 200 Series
Advanced Mode | en
57
Bosch Security Systems
Installation and Operation Manual
AR18-09-B003 | v1.1 | 2010.05
6.6.3
VCA configuration- Profiles
Configure two profiles with different VCA configurations. Save
profiles on your computer's hard drive and load saved profiles
from there. This can be useful if testing a number of different
configurations. Save a functioning configuration and test new
settings. Use the saved configuration to restore the original
settings at any time.
1.
Select a VCA profile and enter the required settings.
2.
If necessary, click
Default
to return all settings to default
values.
3.
Click the
Save...
to save the profile settings to another file.
A new window opens in which to specify the file name and
where to save it.
4.
Click
Load...
to load a saved profile. A new window opens
in which to select the profile file and specify where to save
the file.
To rename a profile:
1.
To rename the file, click the icon to the right of the list field
and enter the new profile name in the field.
2.
Click the icon again. The new profile name is saved.
The current alarm status is displayed for information purposes.
Aggregation time (s)
Set an aggregation time of between 0 and 20 seconds. The
aggregation time always starts when an alarm event occurs. It
extends the alarm event by the value set. This prevents alarm
events that occur in quick succession from triggering several
alarms and successive events in a rapid sequence. No further
alarm is triggered during the aggregation time.
The post-alarm time set for alarm recordings only starts once
the aggregation time has expired.
Analysis type
Select the required analysis algorithm. By default, only
is available — this offers a motion detector and essential
recognition of tampering.