50
en | Advanced Mode
IP Camera 200 Series
AR18-09-B003 | v1.1 | 2010.05
Installation and Operation Manual
Bosch Security Systems
Stream
Select the data stream to be used for standard recordings. (You
can select the data stream for alarm recordings separately and
independently of this setting.)
Alarm recording
Select the
Pre-alarm time
from the list box.
Select the
Post-alarm time
from the list box.
Select the
Alarm stream
to use for alarm recording. The
encoding interval for alarm recording can be selected from the
predefined profiles.
Alarm triggers
Select the alarm type (
Alarm input
/
Motion/Audio alarm
/
Video loss alarm
) that is to trigger a recording. Select the
Virtual alarm
sensors that are to trigger a recording, via RCP+
commands or alarm scripts, for example.
6.5.3
Retention Time
Specify the retention times for recordings. If the available
memory capacity of a medium has been used, older recordings
are only overwritten if the retention time entered here has
expired.
Make sure that the retention time corresponds with the
available memory capacity. A rule of thumb for the memory
requirement is as follows: 1 GB per hour retention time with
VGA for complete frame rate and high image quality.
Enter the required retention time in hours or days for each
recording.
Recording 1
corresponds to Stream 1,
Recording 2
corresponds to Stream 2.