NOTE:
• Any temporary water connections are
detrimental to the correct functioning of
this dispenser.
• During installation only new water supply
pipes must be used. The water supply
line for this dispenser must consist of an
interception valve (tap) and non-return
valve.
• For the correct and safe functioning
of this dispenser, the water mains
must satisfy the criteria detailed in the
specification section of this manual (see
page 44).
• If mains water is greater than 3.5 bar, a
pressure reducing valve (PRV) needs to
be fitted to bring the pressure down to
3bar.
• Fittings and pipes for connection to the
water mains must be food certified.
Optional accessories such as filters and
pre-filters, to be assembled on the water
mains after the interception valve, must
also be certified for food compatibility.
1. Check the main components are present
as per the lists on pages 4 - 5.
2.
Pre-flush and fit the filter in an accessible
position.
3. Position the unit in place, ensuring it is
level and stable.
4. Connect the water supply pipe to the
fitting supplied in the install kit.
5. Once connected to the mains, position a
suitable container at the open end of the
supply pipe and turn on the water to drain
and clean the tube; clear the external filter
and other outer accessories (if attached)
by draining at least 2 litres of water. After
this operation turn off the tap.
6. Connect the open end of the tube to the
8mm push fit located on the dispenser
(see Fig1).
7. Connect the tap supply pipes to the outlet
pipes of the undercounter unit. (see fig3)
8. Always allow adequate connecting pipe
length to enable the unit to be sufficiently
moved for any future disconnection.
9. Turn on the tap making sure there are no
leaks along the supply line (see Fig2).
Fig 2
Fig 1
Fig 3
Co2 Pipe
Tap
Elbows
Co2 Bottle
Water Pipes