Borg & Overström
GB
17
Install & Operation Manual
30-Litre - Initial Cold Water Operation
After carrying out the installation procedures
detailed in the previous chapter, run the initial
cold water operation as follows:
1. Ensure the CO2 bottle is properly
connected to the dispenser (see page 20).
2. Place a container with a capacity of 5
litres under the tap.
3. Dispense at least 3 litres of both ambient
and chilled water.
30-Litre Controls
Power Connection Socket
Note:
the 30-Litre undercounter unit
automatically powers up when the
power lead is connected.
30-Litre - Temperature Control
The cold water temperature control has 3
settings – 4c, 6c and 8c. The undercounter
unit is factory set to 6c.
If any adjustment is required, please carry out
the following steps:
1. Locate the button on the back top left of the
unit (see Fig1).
2. Press and hold the button for
approximately 3 seconds until you hear the
signal beep, continue to hold whilst counting
the number of bleeps. Use adjacent table to
set the temperature:
1 bleep
4°C
2 bleeps
6°C
3 bleeps
8°C
3. To change the setting, each additional
press of the same button will select one of the
alternative settings. This will be shown by the
3 LEDs in the above image.
4. Release the programming button to save
the selected setting.
5. Press and hold the programming button
again and count the number of bleeps to
confirm the setting is saved.
Fig 1
Fig 2
3
secs