Sanitisation Guide
NOTE:
All maintenance operations must be carried out with the dispenser switched off. This operation must
only be carried out by trained staff. Every 6 months a sanitisation procedure is recommended as follows:
Turn off incoming mains
water.
Briefly press chilled
dispense button to
release internal water
pressure from the
machine.
Remove the existing
filter.
Use Sterizen Hand Gel
and put on protective
gloves.
Add 25 ml of Sterizen
30 to a clean and
empty service filter
cartridge.
Connect to filter head.
Turn on incoming water,
allow service
cartridge/doser to fill.
Dispense water using
the chilled button.
Repeat with sparkling
button.