• Ensure a space under the bottom of the hob
casing of 20 mm to ensure a good air circu-
lation of the electronic device.
• If a drawer is placed under the hob, avoid
placing flammable objects in this drawer
(for example: sprays) or non heat-resistant
objects.
• To protect the cut out edge, apply a coat of
varnish or special sealant. Particular care
must be given to applying the adhesive joint
supplied with the hob to prevent any leakage
into the supporting furniture. This gasket
guarantees a correct seal when used in con-
junction with smooth work top surfaces.
• The safety gap between the hob and the coo-
ker hood placed above must respect the indi-
cations of the hood manufacturer. In case of
absence of instructions respect a distance
minimum of 760 mm.
• The connection cord should be free of (me-
chanical) constraints after installation, at all
times.
Electrical connection
• The installation of this appliance and the connection to the electrical network should be en-
trusted only to an electrician whom is aware of the local regulations and which respects them
scrupulously.
• Protection against the parts under tension must be ensured after the building-in.
• The necessary data for connection are on the stickers placed on the hob casing near the con-
nection box.
• The connection to the main must be made using an earthed plug or via an omni polar circuit
breaking device with a contact opening of at least 3 mm.
• The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
Caution!
This appliance is only to be connected to a network 230 V~ 50 Hz.
Always connect the earth wire.
Respect the connection diagram.
The connection box is located underneath, at the back of the hob casing. To open the cover use a
medium screwdriver. Place it in the slits and open the cover.
Mains
Connection
Cable diameter Cable
Protection calibre
230V~1P+N 50Hz
1 Phase + N 3 x 2,5 mm²
H 05 VV - F 25 A *
H 05 RR - F
400V~2P+N 50Hz
2 Phase + N 4 x 1,5 mm²
H 05 VV - F 16 A *
H 05 RR - F
230V~2P+2N 50Hz 2 Phase + 2N 5 x 1,5 mm²
H 05 VV - F 16 A *
H 05 RR - F
* calculated with the simultaneous factor following the standard TN 60 335-2-6/1990