background image

 

3

PROTHO Technical Manual  

 

 

 

 

 

 

         Bores Group S.r.l. 

 
 
Dear Customer, congratulations for having chosen a quality product that will definitely meet your needs. While thanking 
you for your choice, we kindly ask you to carefully look at this Instruction manual before using your new peristaltic 
metering pump. 

 
 

INDEX 

 
1   IMPORTANT DIRECTIONS AND RECOMMENDATIONS 

   

page 4 

 
2   GENERAL CHARACTERISTICS 

   

page 4 

 

2.1 FIELD OF USE 

   

page 4 

 
2.2 FUNCTIONING PRINCIPLE 

   

page 4 

 
2.3 RATING 

   

page 4 

 

3   INSTALLATION 

   

page 4 

 

3.1 POSITIONING 

   

page 4 

 
3.2  CONNECTING TO THE MAINS SUPPLY 

   

page 5 

 
3.3  WATER CONNECTIONS 

   

page 5 

 

4   STARTING 

   

page 6 

 

 4.1 

REGULATING 

THE CAPACITY 

   

page 6 

 

5   MAIN CAUSES OF FAILURE TO FUNCTION 

   

page 7 

 
6   MAINTENANCE AND CLEANING 

   

page 7 

 

6.1  PERIODICAL CHECKS 

   

page 7 

 

7   PERIODS OF NON-OPERATION 

   

page 7 

 
8   DIRECTIONS FOR THE MAINTENANCE FITTER 

   

page 7 

 
9   WARRANTY TERMS 

   

page 8 

 
10   TECHNICAL INFORMATION 

   

page 9 

 
11  EXPLODED VIEW OF THE METERING PUMP WITHOUT CONTAINER 

page 10 

 
12  EXPLODED VIEW OF THE METERING PUMP WITH CONTAINER     

page 11 

 
13   ACCESSORIES AND SPARE PARTS 

   

page 12 

Summary of Contents for PROTHO

Page 1: ...INSTRUCTION MANUAL Peristaltic Pump for cleansing agents PROTHO...

Page 2: ...2 PROTHO Technical Manual Bores Group S r l Rev 01 del 151008...

Page 3: ...NING PRINCIPLE page 4 2 3 RATING page 4 3 INSTALLATION page 4 3 1 POSITIONING page 4 3 2 CONNECTING TO THE MAINS SUPPLY page 5 3 3 WATER CONNECTIONS page 5 4 STARTING page 6 4 1 REGULATING THE CAPACIT...

Page 4: ...away into the environment Arrange for the disposal and the recovery of the materials in accordance with the relevant national laws in force For this reason we urge you to give maintenance work and re...

Page 5: ...not to damage the various components Now connect the wires that come out of the pump container one to earth to the casing of the machine the other to the fastener on the detergent sensor previously i...

Page 6: ...l and water connections of the metering pump are complete you can proceed to starting it When starting the pump for the first time the dishwashing machine has to perform several washing cycles on empt...

Page 7: ...ipe from breaking through wear Maintenance on this component must be carried out by competent and professionally qualified personnel from a Service Centre and demanding the use of original spare parts...

Page 8: ...ss of negligence in use failure to comply with the instructions for the operation of the device or incorrect installation and maintenance carried out by personnel that are not professionally qualified...

Page 9: ...1 0 4 3 2x6 4 3 PDE3 3 0 92 3 3 6 4x1 6 0 1 PDE4 0 1 12 4 0 6 4x1 6 0 1 PDER3 3 0 92 3 3 6 4x1 6 0 1 PBE1 0 0 28 1 0 3 2x6 4 3 PDE8 0 2 24 8 0 6 4x1 6 0 1 PDE8 024 2 24 8 0 6 4x1 6 0 1 PDER8 024 2 24...

Page 10: ...10 PROTHO Technical Manual Bores Group S r l 11 EXPLODED VIEW OF THE METERING PUMP WITHOUT CONTAINER...

Page 11: ...11 PROTHO Technical Manual Bores Group S r l 12 EXPLODED VIEW OF THE METERING PUMP WITH CONTAINER...

Page 12: ...n elbow for detergent injection complete SENSC Sensor for detergent conductimetric control card FILFIC VALFC Stainless steel bottom filter complete Stainless steel bottomfilter with non return valve c...

Page 13: ...plete with pipe fitting TUBS3264ABC Silicone pipe for rinse aid complete with pipe fittine with non returne valve ROCPPC ROCPPBC Support with Protho rollers for detergent complete Support with Protho...

Reviews: